191
42073A-MCU Wireless-02/13
ATmega2564/1284/644RFR2
AVR State
Radio Transceiver State
Powerchain
off
(2,3)
DEEP SLEEP
off (SLEEP or power reduction)
off
(7)
Notes:
1. Idle
2. Power Down
3. Power Save
4. ADC Noise Reduction Mode
5. Standby
6. Extended Standby
7. If the OCDEN fuse is programmed, the Power-chain is always on
12.5.2 SRAM with Data Retention
It is necessary to prevent any data loss of the SRAM when setting the CPU in one of
the DEEP_SLEEP modes. For that purpose the SRAM blocks will not be completely
switched off if the power-chain is disabled. The supply voltage for any individual SRAM
block is decreased to reduce its leakage current but guaranteeing its data retention.
The SRAM memory is divided into 4kByte blocks. Each block can be fully switched off
by setting the correspondent bit (PRRAM0 ... PRRAM3) in register PRR2 (see
"PRR2 –switch off unused SRAM memory to save power and to reduce leakage currents.
Every SRAM block can be enabled again by resetting the respective bit (PRRAM0 ...
PRRAM3) of register PRR2. For each SRAM block n the bit DRTSWOK of the
corresponding register DRTRAMn shows the state of the DRT switch (logic high means
SRAM block can be accessed).
If the power-chain is switched off during deep-sleep modes, the content of the SRAM
blocks must be sustained. To provide data retention and lowest leakage current, a data
retention block controls the SRAM behavior during deep-sleep. Since the leakage
current is dramatically depending from the voltage of the SRAM, the supply voltage can
be decreased by enabling the data retention mode DRT.
Every SRAM block n is controlled by its assigned register DRTRAMn. The bit ENDRT
enables the data retention mode during deep-sleep. If this bit is zero, the respective
SRAM block is completely switched off.
Table 12-3. SRAM behavior while in deep-sleep mode
ENDRT
Power-chain
SRAM supply voltage
1
ON
1.8V (DVDD)
0
ON
1.8V (DVDD)
1
off
Reduced
0
off
Disconnected
The lower 4-bit of the register DRTRAMn are reserved and should not be changed. The
reset value of the DRT voltage settings are preprogrammed during the manufacturing
process and need not to be changed.
12.5.3 Voltage Regulators (AVREG, DVREG)
The main features of the Voltage Regulator blocks are:
Bandgap stabilized 1.8V supply for analog and digital domain;
Low dropout (LDO) voltage regulator;