HM17CM4096
- 48 -
(30) INSTRUCTION
INSTRUCTION TABLE (1)
CODE(80 series I/F)
RE flag
Register address
Control address
INSTRUCTION
CS
RS
RD
WR RE2 RE1 RE0 D7
D6
D5
D4
D3
D2
D1
D0
function
X address(lower)
0
1
1
0
0
0
0
0
0
0
0
AX3 AX2 AX1 AX0
Write in to display RAM
X address(upper)
0
1
1
0
0
0
0
0
0
0
1
*
AX6 AX5 AX4
Y address(lower)
0
1
1
0
0
0
0
0
0
1
0
AY3 AY2 AY1 AY0
RAM
Y
Y address(upper)
0
1
1
0
0
0
0
0
0
1
1
AY7 AY6 AY5 AY4
display start line set (lower)
0
1
1
0
0
0
0
0
1
0
0
LA3 LA2 LA1 LA0
display start line set (upper)
0
1
1
0
0
0
0
0
1
0
1
LA7 LA6 LA5 LA4
RAM Y address setting
corresponds to scan start
line of common driver.
N line inversion set (lower)
0
1
1
0
0
0
0
0
1
1
0
N3
N2
N1
N0
N line inversion set (upper)
0
1
1
0
0
0
0
0
1
1
1
N7
N6
N5
N4
quantity
inversion
setting
of
line
display control (1)
0
1
1
0
0
0
0
1
0
0
0
SHI
FT
MO
N
ALL
ON
ON/
OFF
SHIFT: common shift direction set,
MON: BW/gradation display,
ALLON: all on ,
ON/OFF: display ON/OFF control
REV: display positive / negative,
NLIN: n line inversion ON/OFF,
SWAP: display data swap,
REF: segment positive / negative
WIN: window selection,
AIM: increment timing selection,
AYI:Y increment,
AXI:X increment
AMPON: internal OP Amp. ON,
HALT: power save
DCON: boosting circuit ON, ACL:
reset
display control (2)
0
1
1
0
0
0
0
1
0
0
1
REVNLI
N
SWA
P
REF
increment control
0
1
1
0
0
0
0
1
0
1
0
WIN AIM
AYI
AXI
power control
0
1
1
0
0
0
0
1
0
1
1
AMP
ON
HAL
T
DCO
N
ACL
LCD duty set
0
1
1
0
0
0
0
1
1
0
0
DS3 DS2 DS1 DS0 LCD driver duty ratio set
boosting coefficient set
0
1
1
0
0
0
0
1
1
0
1
*
VU2 VU1 VU0 Boosting times set
bias ratio set
0
1
1
0
0
0
0
1
1
1
0
*
B2
B1
B0
LCD drive bias set
RE register set
0
1
1
0
0/1
0/1
0/1
1
1
1
1
TST RE2 RE1 RE0 RE flag set
Notice 1) * mark is Don’t Care
Notice 2) The commands that upper/lower register settings are demanded are effective at the point of commands input.
But electric volume is effective after upper and lower register setting.