參數(shù)資料
型號: T7237A
英文描述: Compliance with the New ETSI PSD Requirement
中文描述: 符合新的ETSI PSD的要求
文件頁數(shù): 76/116頁
文件大小: 1056K
代理商: T7237A
Data Sheet
January 1998
T7256 Single-Chip NT1 (SCNT1) Transceiver
72
Lucent Technologies Inc.
Application Briefs
(continued)
Available Tools for Evaluation of the T7256
(continued)
Resetting SCNT1
The SPEC_V2 board has a push-button RESET switch
(S1) that may be used to RESET the 8751 microcon-
troller on the SPEC_V2. Asserting RESET will restart
the SPEC_V2 firmware. Upon power-on or RESET, the
SPEC_V2 displays the opening screen on the terminal,
and it appears as follows:
Lucent Technologies
SPEC_V2 Control Software, V 1.0, 6/2/96
(type "help" (lower case) for a list of commands)
At this point, any of the commands in Table 33 may be
entered.
If the current test mode is either single pulse or eye
pattern mode, the microcontroller will reset the SCNT1
when exiting that mode. This is necessary because the
only way to exit these test modes is by resetting
SCNT1 or cycling the power. The reset is accomplished
by pulling the SCNT1 RESET line (pin 43) low. Note
that this requires that any device on the UUT that
drives that RESET pin must have an open-drain or 3-
statable type of output. If RESET cannot be pulled low
due to device contention on the UUT, the UUT must be
powered down to get the SCNT1 out of test mode.
Notes on Single Pulse Mode
Note that, when a single pulse is output on the U-inter-
face, the following will be observed: approximately
25 ms after the rising edge of a single positive pulse, a
small positive glitch will occur. This is more pronounced
on +1 pulses than on +3 pulses, where it is hardly
detectable. The cause of the glitch is well understood
and was thoroughly investigated during the chip devel-
opment to ensure that it causes no harm under normal
operating conditions.
The explanation is as follows. The transmit sigma-delta
modulator in the SCNT1 is RESET whenever a transi-
tion from nonzero data to zero data occurs. It was
designed this way for ease of production testing, so
that the sigma-delta is always initialized to a known
state. This resetting is what causes the glitch. In normal
operation, the nonzero to zero case will never occur,
except when the transceiver is going from an active
state to RESET. In this case, there is a control signal
that grounds the input to the line driver to force it to
transmit 0 V (i.e., forces it into a low-impedance state—
this feature grew out of the ANSI requirements), so the
sigma-delta modulator has no effect in this case.
Thus, the glitch never occurs in normal operation and
should be ignored when observing the pulse output.
This has been confirmed independently at Bellcore
using their test bed that digitizes the chip output under
normal operation, and then reconstructs the pulse
shape using DSP filtering techniques.
相關(guān)PDF資料
PDF描述
T7256A Compliance with the New ETSI PSD Requirement
T7288 CEPT/E1 Line Interface(CEPT/E1 線接口)
T7290A DS1/T1/CEPT/E1 Line Interface(DS1/T1/CEPT/E1 線接口)
T7295-1 E3 Integrated Line Receiver(E3 集成線接收器)
T7295-6 DS3/SONET STS-1 Integrated Line Receiver(DS3/SONET STS-1 集成線接收器)
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
T7240 制造商:TE Connectivity 功能描述:
T7-241A5 功能描述:撥動開關(guān) ON NONE OFF 2 Pole Standard Bat Handle RoHS:否 制造商:OTTO 觸點形式: 開關(guān)功能: 電流額定值: 電壓額定值 AC: 電壓額定值 DC: 功率額定值: 端接類型: 安裝風(fēng)格: 端子密封: 觸點電鍍: 照明:
T7-241B1 制造商:OTTO 功能描述:Toggle Switches ON NONE ON 2 Pole Standard Bat Handle 制造商:OTTO Engineering Inc 功能描述:Switch Toggle ON None ON DPDT Bat Toggle PC Pins 16A 115VAC 28VDC PC Mount with Threads
T7-241B5 功能描述:撥動開關(guān) ON NONE ON 2 Pole Standard Bat Handle RoHS:否 制造商:OTTO 觸點形式: 開關(guān)功能: 電流額定值: 電壓額定值 AC: 電壓額定值 DC: 功率額定值: 端接類型: 安裝風(fēng)格: 端子密封: 觸點電鍍: 照明:
T7-241C5 制造商:OTTO 功能描述:Toggle Switches (ON) NONE OFF 2 Pole Standard Bat Handle 制造商:OTTO Engineering Inc 功能描述:Switch Toggle (ON) None OFF DPST Bat Toggle PC Pins 16A 115VAC 28VDC PC Mount with Threads