TLC2943
HIGH-PERFORMANCE DUAL PHASE-LOCKED BUILDING BLOCK
SLAS249 – NOVEMBER 1999
7
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature (unless otherwise noted)
Supply voltage (each supply), V
DD
(see Note 1)
Input voltage range (each input), V
I
(see Note 1)
Input current (each input), I
I
Output current (each output), I
O
Continuous total power dissipation at (or below) T
A
= 25
°
C (see Note 2)
Operating free-air temperature range, T
A
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 in) from case for 10 seconds
7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–0.5 to V
DD
+ 0.5 V
±
20 mA
±
20 mA
1160 mW
. . . . . . . . . . . . . . . . . . . . . . . .
–20
°
C to 75
°
C
–65
°
C to 150
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
260
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. All voltage values are with respect to network ground terminal.
2. For operation above 25
°
C free-air temperature, derate linearly at the rate of 9.3 mW/
°
C.
recommended operating conditions
MIN
2.85
NOM
MAX
3.15
UNIT
VDD = 3 V
VDD = 3.3 V
VDD = 5 V
3
Supply voltage (each supply, see Notes 3 and 4 ), VDD
3.15
3.3
3.45
V
4.75
5
5.25
Input voltage range (input except for VCOIN_1, 2), VI
Output current (each output), IO
Control voltage, VCOIN
0
VDD
±
2
VDD
55
V
0
mA
1
V
VDD = 3 V
VDD = 3.3 V
VDD = 5 V
VDD = 3 V
VDD = 3.3 V
VDD = 5 V
37
Clock frequency, f
37
60
MHz
43
100
1.8
2.7
Oscillation frequency range set resistor (each RBIAS), RBIAS VCO
1.8
3.0
k
2.2
3.0
Top operating temperature range
NOTES:
3. It is recommended that the logic supply terminal (LOGIC VDD) and the VCO supply terminal (VCO VDD) be at the same voltage and
separated from each other.
4. Insert bypass capacitors locating the nearest point to each power supply terminal.
–20
75
C