Data Sheet
January 1998
T7289A DS1 Line Interface
9
Lucent Technologies Inc.
Receive Converter
(continued)
Figure 6. DS1 Jitter Tolerance
5-4353(C)
10.0
1.0
0.1
0.01
0.1
1.0
10
100
I
(
JITTER FREQUENCY (kHz)
(500, 5)
(10, 5)
(8k, 0.1)
(50k, 0.1)
(70k, 0.3)
MEASURED T7289A PERFORMANCE
BER = 10
–6
(2
20
– 1 PATTERN)
(300, 10)
BELLCORE TR-TSY-00170 AND
PUB 43801 SPECIFICATION (1/8 PATTERN)
PUB 43802
SPECIFICATION
(2
20
– 1 PATTERN)
MEASURED T7289A
PERFORMANCE
BER = 10
–6
(1/8 PATTERN)
(10k, 0.3)
JITTER
FREQUENCY
(kHz)
2.0
8.0
20
30
40
50
60
70
MEASURED DATA POINTS
1/8 PATTERN
JITTER
AMPLITUDE
(U.I.pp)
6.5
1.1
0.66
0.52
0.49
0.48
0.48
0.48
JITTER
FREQUENCY
(kHz)
20
8.0
20
30
40
50
JITTER
AMPLITUDE
(U.I.pp)
10
1.8
0.7
0.45
0.45
0.45
2
20
– 1 PATTERN
Digital Logic
The logic provides alarms, optional B8ZS coding, blue-
signal insertion (AIS) circuits, and maintenance loop-
backs. It accepts dual-rail or single-rail data patterns.
Single-Rail/Dual-Rail Option
To implement the rail-select feature, the dual pin (pin 23)
is cleared for single-rail mode and set for dual-rail mode.
When single-rail mode is selected, pin 8 (TDATA/
TPDATA) accepts transmit data and pin 6 (
RDATA
/
RPDATA) outputs inverted receive data. When dual-rail
mode is selected, pin 8 (TDATA/TPDATA) accepts the
positive rail transmit data, and pin 3 (BZSC/TNDATA) is
reconfigured to accept negative rail transmit data. Pin 6
(
RDATA
/RPDATA) outputs positive rail receive data, and
pin 4 (BPV/RNDATA) is reconfigured to output negative
rail receive data. In dual-rail mode, the B8ZS and bipo-
lar violation functions are disabled.
For single-rail operation, TDATA is active-high and
RDATA
is active-low. For dual-rail operation, TPDATA,
TNDATA, RPDATA, and RNDATA are all active-high.
This interface scheme is consistent with the dual-rail
interfaces of other Lucent Line Interface products.