參數(shù)資料
型號(hào): RXC101
廠商: RF Monolithics, Inc.
英文描述: Multi-channel High data rate Programmable
中文描述: 多通道可編程數(shù)據(jù)率高
文件頁(yè)數(shù): 22/33頁(yè)
文件大?。?/td> 546K
代理商: RXC101
22
Automatic Frequency Adjust Register
[POR=C6F7h]
Bit
Bit
Bit
Bit
Bit
Bit
Bit
Bit
Bit
Bit
Bit
Bit
Bit
Bit
Bit
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
1
1
0
0
0
1
1
0
AUTO1
AUTO0
RNG1
RNG0
STRB
ACCF
OFFEN
AFEN
The AFA (Automatic Frequency Adjust) Register configures:
Manual or Automatic frequency offset adjustment
Calculation of the offset value and write to the Status Register
Fine offset adjustment control
The AFA (Automatic Frequency Adjust) Register controls and configures the frequency adjustment range
and mode for keeping the transmitter and receiver frequency locked, providing for an optimal link. The
AFA may be manually controlled by an external processor by asserting a strobe signal to initiate a
sample, or may be setup for automatic operation. The AFA also calculates the offset of the transmit and
receive frequency. This offset value is included in the status register read and the AFA must be disabled
during the status read to ensure reporting good offset accuracy.
Bit [15..8] -
Command Code:
These bits are the command code that is sent serially to the processor that
identifies the bits to be written to the Automatic Frequency Adjust Register.
Bit [7..6] –
Mode Selection:
These bits select Automatic or manual operation. When set to Manual
operation, the RXC101 will take a sample when a strobe signal (See Bit [3]) is written to the
register. There are four modes of operation. See Table 11 below for configuration.
TABLE 11.
Mode Operation
Mode(0,1)
– The circuit takes a measurement only once after power-up. This maximizes the distance
that can be achieved for a single link.
Mode(1,0)
– When the Valid Data Indicator (VDI) pin is low, indicating poor receiving conditions, the
offset register is automatically cleared. Use this setting when receiving from several different
transmitters that are operating very close to the same frequencies.
Mode(1,1)
– This setting is best used when receiving from a single transmitter. The measured offset
value is kept independent of the state of the VDI signal.
Bit [5..4] –
Allowable Frequency Offset:
These bits select the amount of offset allowable between
Transmitter and Receiver frequencies. The allowable range can be specified as in Table 12
below.
TABLE 12.
Automatic fOFFSET Mode
Mode Off
Run Once after Pwr-up
Keep offset during Rcv ONLY
Keep offset indep of VDI state
AUTO1
0
0
1
1
AUTO0
0
1
0
1
Freq Offset Range
No Limit
+15*fres/-16*fres
+7*fres /-8*fres
+3*fres /-4*fres
RNG1
0
0
1
1
RNG0
0
1
0
1
相關(guān)PDF資料
PDF描述
S08A60 SCHOTTKY BARRIER RECTIFIERS(8A,30-60V)
S08A30 SCHOTTKY BARRIER RECTIFIERS(8A,30-60V)
S08A40 SS490 Series Basic Miniature Ratiometric Linear Hall-Effect Sensor; radial lead IC package
S08A50 SCHOTTKY BARRIER RECTIFIERS(8A,30-60V)
S08A70 SCHOTTKY BARRIER RECTIFIERS(8A,70-100V)
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
RXC101M2CBK-1325P 功能描述:鋁質(zhì)電解電容器 - 帶引線 160V 100uF 20% RoHS:否 制造商:Kemet 引線類型: 電容:220 uF 容差:20 % 電壓額定值:25 V 工作溫度范圍: 端接類型:Radial 外殼直徑:8 mm 外殼長(zhǎng)度:11 mm 引線間隔:5 mm 產(chǎn)品:General Purpose Electrolytic Capacitors 封裝:Bulk
RXC101M2CBK-1325S 制造商:Surge Components Inc 功能描述:CAP ALUM 100UF 160V ?20% 3000LHRS 12.5 X 25 - Bulk
RXC101M2CSA-1325S 制造商:Surge Components Inc 功能描述:CAP ALUM 100UF 160V ?20% 3000LHRS 12.5 X 25 - Ammo Pack
RXC101M2CTA-1325S 制造商:Surge Components Inc 功能描述:CAP ALUM 100UF 160V ?20% 3000LHRS 12.5 X 25 - Ammo Pack
RXC101M2DBK-1625P 功能描述:鋁質(zhì)電解電容器 - 帶引線 200V 100uF 20% RoHS:否 制造商:Kemet 引線類型: 電容:220 uF 容差:20 % 電壓額定值:25 V 工作溫度范圍: 端接類型:Radial 外殼直徑:8 mm 外殼長(zhǎng)度:11 mm 引線間隔:5 mm 產(chǎn)品:General Purpose Electrolytic Capacitors 封裝:Bulk