Internet Data Sheet
Rev. 1.01, 2006-09
03292006-ZZHP-PR83
28
HYS72T[32/64]xxxHP–[3S/3.7]–A
Registered DDR2 SDRAM Modules
Data hold skew factor
Average periodic refresh Interval
t
QHS
t
REFI
—
—
—
75
450
7.8
3.9
—
ps
μ
s
μ
s
ns
14)15)
16)21)
Auto-Refresh to Active/Auto-Refresh
command period
Auto-Refresh to Active/Auto-Refresh
command period
Auto-Refresh to Active/Auto-Refresh
command period
Auto-Refresh to Active/Auto-Refresh
command period
Precharge-All (4 banks) command period
Precharge-All (8 banks) command period
Read preamble
Read postamble
Active bank A to Active bank B command
period
t
RFC
17)
t
RFC
105
—
ns
18)
t
RFC
127.5
—
ns
19)
t
RFC
197.5
—
ns
20)
t
RP
t
RP
t
RPRE
t
RPST
t
RRD
t
RP
+ 1
t
CK
15 + 1
t
CK
0.9
0.40
7.5
10
7.5
0.25 x
t
CK
0.40
15
—
—
1.1
0.60
—
—
—
—
0.60
—
ns
ns
t
CK
t
CK
ns
ns
ns
t
CK
t
CK
ns
14)
14)
14)21)
16)23)
Internal Read to Precharge command delay
Write preamble
Write postamble
Write recovery time for write without Auto-
Precharge
Write recovery time for write with Auto-
Precharge
Internal Write to Read command delay
Exit power down to any valid command
(other than NOP or Deselect)
Exit active power-down mode to Read
command (slow exit, lower power)
Exit precharge power-down to any valid
command (other than NOP or Deselect)
Exit Self-Refresh to non-Read command
Exit Self-Refresh to Read command
1) For details and notes see the relevant QIMONDA component data sheet
2)
V
DDQ
= 1.8 V
±
0.1 V;
V
DD
= 1.8 V
±
0.1 V. See notes
5)6)7)8)
3) Timing that is not specified is illegal and after such an event, in order to guarantee proper operation, the DRAM must be powered down
and then restarted through the specified initialization sequence before normal operation can continue.
4) Timings are guaranteed with CK/CK differential Slew Rate of 2.0 V/ns. For DQS signals timings are guaranteed with a differential Slew
Rate of 2.0 V/ns in differential strobe mode and a Slew Rate of 1 V/ns in single ended mode.
5) The CK / CK input reference level (for timing reference to CK / CK) is the point at which CK and CK cross. The DQS / DQS, RDQS/ RDQS,
input reference level is the crosspoint when in differential strobe mode.
6) Inputs are not recognized as valid until
V
REF
stabilizes. During the period before
V
REF
stabilizes, CKE = 0.2 x
V
DDQ
is recognized as low.
7) The output timing reference voltage level is
V
TT
.
t
RTP
t
WPRE
t
WPST
t
WR
22)
WR
t
WR
/
t
CK
t
CK
23)
t
WTR
t
XARD
10
2
—
—
ns
t
CK
24)
25)
t
XARDS
6 – AL
—
t
CK
25)
t
XP
2
—
t
CK
t
XSNR
t
XSRD
t
RFC
+10
200
—
—
ns
t
CK
Parameter
Symbol
DDR2–400
Unit
Note
1)2)3)4)5)
6)7)
Min.
Max.