Fast AMBA Peripherals
12-19
GMS30C7201 Data Sheet
12.3.4 Ir Control Register
The Ir Control Register (IrCon) contains seven different bit-fields which control various
functions for the MIr and FIr.
Baud Rate Divisor (BRD)
The 1-bit baud rate divisor (BRD) field is used to select the baud or bit rate of the MIr.
Two different baud rates can be selected:0.576Mbit/s and 1.152Mbit/s. The baud rate
generator uses the 48MHz clock generated by the on-chip PLL, divided down to the
current data rate as defined by the BRD bit. The receive baud clock is synchronized
with the data steam each time a positive edge transition is detected on the receive data
line.
Thus:
when BRD=0, MIr operates at 0.576Mbit/s
when BRD=1, MIr operates at 1.152Mbit/s
This bit has no effect when the FIr is selected.
Transmit buffer Underrun Select (TUS)
The transmit buffer underrun select (TUS) bit is used both to select what action to take
as a result of a transmit buffer underrun, as well as mask or enable the transmit buffer
underrun interrupt.
When TUS=0, transmit buffer underruns are used to signal the transmit logic that the
end of the frame has been reached. When the transmit buffer experiences an underrun,
the CRC value which is calculated continuously on outgoing data is loaded to the serial
shifter and transmitted, followed by the stop flag and SIP pulse. Also when TUS=0, the
transmit buffer interrupt is masked and the state of the transmit buffer underrun (TUR)
status bit is ignored by the interrupt controller.
When TUS=1, transmit buffer underruns are used to signal the transmit logic that the
end of the frame has not yet been reached and that the rate in which data is supplied
to the transmit buffer is not sufficient. When the transmit buffer experiences an
underrun zeroes are continuously output by the transmitter to signal an abort condition
until data is once again available within the transmit buffer, and the CRC value is
discarded. Additionally, when TUS=1, the transmit buffer underrun interrupt is enabled,
and whenever TUR is set (one) an interrupt request is made to the interrupt controller.
To change the state of this bit during operation, the user should fill the transmit buffer
to ensure TUS is not written at the same time the transmit buffer underruns. Note that
programming TUS=0 does not affect the current state of TUR or the transmit buffer
logic
’
s ability to set and clear TUR, it only blocks the generation of the interrupt request.
TUS is useful for ensuring that frames are not prematurely ended due to an unexpected
transmit buffer underrun. At the start of a frame the user may configure TUS=1 such
that any underrun signals an abort to the off-chip receiver. Just before the end of the
frame the user may then configure TUS=0, allowing the remaining data to be output by
the transmit logic. The buffer then underruns, causing the CRC, stop flag, and SIP to
be transmitted.
Transmit Enable (TXE)
The transmit enable (TXE) bit is used to enable and disable the MIr/FIr transmit sub-
module selected using the IrEnable register. When TXE=0, the transmit logic is
disabled and its clocks are turned off to conserve power. When TXE=1, the transmitter
logic is enabled for IrDA transmission. It is required that the user first program all other
control bits before setting TXE. If the TXE bit is cleared to zero while the is actively
transmitting data, transmission is stopped immediately, all data within the transmit