Altera Corporation
 21
Arithmetic Functions
lpm_counter 
Parameterized Counter
The 
lpm_counter
 function is a full- 
featured counter with loading, up/ down 
control, clock, and count enabling and 
clearing.
Ports (Part 1 of 2)
Name
Type
Required
Description
sset
Input
No
Synchronous set input. Sets the counter on the next active clock edge.
Default = 0. Sets 
q[]
 outputs to all 1s, or to the value specified by 
LPM_SVALUE
. If both 
sset
 and 
sclr
 are used and both are asserted, 
sclr
is dominant. For outputs such as 
q[]
 and 
eq[]
, 
sset
 affects the output 
before polarity is applied.
Synchronous load input. Loads the counter with data on the next active clock 
edge. Default = 0. If 
sload
 is used, 
data[]
 must be connected.
Controls the direction of the count. High (1) = count up. Low (0) = count down.
Default = up (1). If the 
LPM_DIRECTION
 parameter is used, the 
updown
 port 
cannot be connected. If 
LPM_DIRECTION
 is not used, the 
updown
 port is 
optional.
Count enable input. Disables count when low (0) without affecting 
sload
, 
sset
, or 
sclr
. Default = 1.
Parallel data input to the counter. This port is 
LPM_WIDTH
 wide. Uses 
aload
and/or 
sload
.
Positive-edge-triggered clock.
sload
Input
No 
updown
Input
No
cnt_en
Input
No
data[]
Input
No
clock
Input
Yes
clk_en
Input
No
Clock enable input. Enables all synchronous activities. Default = 1.
sconst
Input
No
This port is provided only for backwards-compatibility in MAX+PLUS II 
pre-version 6.0 designs. Altera does not recommend using this port for new 
designs.
Synchronous clear input. Clears the counter on the next active clock edge.
Default = 0. If both 
sset
 and 
sclr
 are used and both are asserted, 
sclr
 is 
dominant. For outputs such as 
q[]
 and 
eq[]
, 
sclr
 affects the output before 
polarity is applied.
sclr
Input
No
sset
sload
updown
cnt_en
data[]
clock
clk_en
sconst
sclr
LPM_COUNTER
LPM_SVALUE=
LPM_AVALUE=
LPM_MODULUS=
LPM_DIRECTION=
LPM_WIDTH=
q[]
eq[]
a
a
a
a