TLV4110, TLV4111, TLV4112, TLV4113
FAMILY OF HIGH OUTPUT DRIVE OPERATIONAL
AMPLIFIERS WITH SHUTDOWN
SLOS289B – DECEMBER 1999 – REVISED DECEMBER 2000
3
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
DD
(see Note 1)
Differential input voltage, V
ID
Input voltage range, V
I
Output current, I
O
(see Note 2)
Continuous /RMS output current, I
O
(each output of amplifier): T
J
≤
105
°
C
7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
±
V
DD
±
V
DD
800 mA
350 mA
110 mA
500 mA
155 mA
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
T
J
≤
150
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
See Dissipation Rating Table
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds
Peak output current, I
O
(each output of amplifier: T
J
≤
105
°
C
T
J
≤
150
°
C
Continuous total power dissipation
Operating free-air temperature range, T
A
: C suffix
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0
°
C to 70
°
C
–40
°
C to 125
°
C
I suffix
Maximum junction temperature, T
J
Storage temperature range, T
stg
150
°
C
–65
°
C to 150
°
C
260
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. All voltage values, except differential voltages, are with respect to GND.
2. To prevent permanent damage the die temperature must not exceed the maximum junction temperature.
DISSIPATION RATING TABLE
PACKAGE
θ
JC
(
°
C/W)
θ
JA
(
°
C/W)
TA
≤
25
°
C
POWER RATING
TA
=
125
°
C
POWER RATING
D (8)
38.3
176
710 mW
142 mW
D (14)
DGN (8)
DGQ (10)
26.9
122.3
1022 mW
204.4 mW
4.7
52.7
2.37 W
474.4 mW
4.7
52.3
2.39 W
478 mW
P (8)
41
104
1200 mW
240.4 mW
N (14)
32
78
1600 mW
320.5 mW
See The Texas Instruments document, PowerPAD Thermally Enhanced Package Application Report(literature number
SLMA002), for more information on the PowerPAD package. The thermal data was measured on a PCB layout based
on the information in the section entitled Texas nstruments Recommended Board or PowerPADon page 33 of the before
mentioned document.
recommended operating conditions
MIN
MAX
UNIT
Supply voltage, VDD
Common-mode input voltage range, VICR
2.5
6
V
0
VDD–1.5
V
Operating free air temperature TA
Operating free-air temperature, TA
C-suffix
0
70
°
C
I-suffix
–40
125
V(on)
VDD = 3 V
VDD = 5 V
VDD = 3 V
VDD = 5 V
2.1
3.8
V
Shutdown turn on/off voltage level§
V(off)
0.9
1.65
§Relative to GND