January 11, 2006 S29GL-A_00_A5
S29GL-A MirrorBit Flash Family
51
Pr el im i n a r y
If DQ5 goes high during a program or erase operation, writing the reset com-
mand returns the device to the read mode (or erase-suspend-read mode if the
device was in Erase Suspend).
Note that if DQ1 goes high during a Write Buffer Programming operation, the
system must write the Write-to-Buffer-Abort Reset command sequence to reset
the device for the next operation.
Autoselect Command Sequence
The autoselect command sequence allows the host system to read several iden-
tifier codes at specific addresses:
Note: The device ID is read over three cycles. SA = Sector Address
The autoselect command sequence is initiated by first writing two unlock cycles.
This is followed by a third write cycle that contains the autoselect command. The
device then enters the autoselect mode. The system may read at any address
any number of times without initiating another autoselect command sequence:
The system must write the reset command to return to the read mode (or erase-
suspend-read mode if the device was previously in Erase Suspend).
Enter/Exit Secured Silicon Sector Command Sequence
The Secured Silicon Sector region provides a secured data area containing an
8-word/16-byte random Electronic Serial Number (ESN). The system can access
the Secured Silicon Sector region by issuing the three-cycle Enter Secured Sili-
con Sector command sequence. The device continues to access the Secured
Silicon Sector region until the system issues the four-cycle Exit Secured Silicon
Sector command sequence. The Exit Secured Silicon Sector command sequence
page 62 show the address and data requirements for both command sequences.
formation. Note that the ACC function and unlock bypass modes are not available
when the Secured Silicon Sector is enabled.
Word Program Command Sequence
Programming is a four-bus-cycle operation. The program command sequence is
initiated by writing two unlock write cycles, followed by the program set-up com-
mand. The program address and data are written next, which in turn initiate the
Embedded Program algorithm. The system is not required to provide further
controls or timings. The device automatically provides internally generated pro-
gram command sequence, respectively.
Identifier Code
A7:A0
(x16)
A6:A-1
(x8)
Manufacturer ID
00h
Device ID, Cycle 1
01h
02h
Device ID, Cycle 2
0Eh
1Ch
Device ID, Cycle 3
0Fh
1Eh
Secured Silicon Sector Factory Protect
03h
06h
Sector Protect Verify
(SA)02h
(SA)04h