Advanced Installation Steps
be unable to retrieve its copy of this (and other) file(s). Depending on the particular service
being requested, fulfilling the request may take a long time, or may fail completely.
If you do not plan on using NIS, defer installation of NIS during the installation by pressing
<F8> on the NIS configuration screen. If you decide at a later time to install NIS, you can do
so using the pkgadd(1) command. Go to
step 3
.
3. Install the Netscape browser. The Netscape browser is provided in the SCO UnixWare CD-
ROM Disk 2 of 3.
4. After completing the UnixWare installation, connect the remaining SCSI disks to be
configured as part of the RAID subsystem.
5. Boot the system, then insert the GSU31 CD-ROM in the CD-ROM drive and mount the CD-
ROM.
a. Create a directory to mount the file. For example, type
“
mkdir cdfiles
”
at the prompt.
b. Mount the CD-ROM to the folder by typing
“
mount
–
F cdfs
–
r /dev/cdrom/cdrom1 /
cdfiles
”
6. Install all the Packages/Services Requirements first before installing the components
packages. See
Table 2-4
for a complete list of all Packages/Services Requirements.
Table 2-4
lists the installation components and preinstallation requirements provided by
GSU31 for UnixWare.
7. Launch the installer by typing the following:
a. Type
“
cd /cdfiles/os_setup/unixware
”
b. Type
“
sh install
”
to start the install script.
c. Select option 1 (by typing 1) to install the requirements and components (
Figure 2-53
).
The launched scripts are shown in
Figure 2-54
.
Packages can be individually installed by typing the package number listed on the screen
as shown in
Figure 2-54
. To select all packages, press Enter. To install multiple packages,
type <package number>, <package number> etc. For example, 1,2,4 etc., then press Enter.
After completing the installation type
quit
and hit Enter to return to the main menu.
Packages which have been previously installed will only be updated if the revision
number of the currently installed package is older or newer.
8. After completing the installation of the components launch the application using the
commands in
Table 2-6
.
9. Reboot the system and create a RAID volume. See
Section 2.2, RAID Configuration Utility
.
10. Reboot the system into UnixWare and install the browser if necessary. The Netscape browser
is provided in the SCO UnixWare CD-ROM Disk 2 of 3.
11. After completing the installation of the components launch the application using the
commands in
Table 2-6
.
Launching Storage Console
1. Log on to the server as root or equivalent. Launch Netscape, type http://localhost:360/ and hit
Enter
.
2. Click on the IOP # card that you want to configure; for example, IOP0, IOP1 etc.
3. Click on the RAID Storage Console link. The Storage Console appears.