Temperature and Gas Gauge Register
(TMPGG)
TMPGG Temperature Bits
7
6
5
4
3
2
1
0
TMP3
TMP2
TMP1
TMP0
-
-
-
The read-only TMPGG register (address=02h) contains
two data fields. The first field contains the battery tem-
perature. The second field contains the available charge
from the battery.
The bq2013H contains an internal temperature sensor.
The temperature is used to set charge efficiency factors
as well as to adjust the self-discharge coefficient. The
temperature register contents may be translated as
shown in Table 10.
The bq2013H calculates the available charge as a func-
tion of NAC and a full reference, either LMD or PFC.
The results of the calculation are available via the dis-
play port or the gas gauge field of the TMPGG register.
The register is used to give available capacity in
116
in-
crements from 0 to
1516
.
TMPGG Gas Gauge Bits
7
6
5
4
3
2
1
0
-
-
-
-
GG3
GG2
GG1
GG0
Nominal Available Charge Register (NAC)
The NACH register (address=03h) and the NACL regis-
ter (address=17h) are the main gas gauging registers for
the bq2013H. The NAC registers are incremented dur-
ing charge actions and decremented during discharge
and self-discharge actions.
charge/discharge efficiency are applied automatically to
NAC. NACH and NACL are set to 0 during a bq2013H
reset.
The correction factors for
Battery Identification Register (BATID)
The read/write BATID register (address=04h) is avail-
able for use by the system to determine the type of bat-
tery pack. The BATID contents are retained as long as
V
is greater than 2V. The contents of BATID have no
effect on the operation of the bq2013H. There is no de-
fault setting for this register.
Last Measured Discharge Register (LMD)
LMD is a read/write register (address=05h) that the
bq2013H uses as a measured full reference.
bq2013H adjusts LMD based on the measured discharge
capacity of the battery from full to empty. In this way
the bq2013H updates the capacity of the battery. LMD
is set to PFC during a bq2013H reset.
The
Secondary Status Flags Register (FLGS2)
The read-only FLGS2 register (address=06h) contains
the secondary bq2013H flags.
The
 charge rate
 flag (CR) is used to denote the fast
charge regime.
Fast charge is assumed whenever a
charge action is initiated. The CR flag remains asserted
if the charge rate does not fall below 2 NAC counts/s.
The CR location is:
FLGS2 Bits
7
6
5
4
3
2
1
0
CR
-
-
-
-
-
-
-
Where CR is:
0
When charge rate falls below 2 counts/sec
1
When charge rate is above 2 counts/sec
The fast charge regime efficiency factors are used when
CR = 1. When CR = 0, the trickle charge efficiency fac-
13
bq2013H
TMP3
TMP2
TMP1
TMP0
Temperature
0
0
0
0
T < -30°C
0
0
0
1
-30°C < T < -20°C
0
0
1
0
-20°C < T < -10°C
0
0
1
1
-10°C < T < 0°C
0
1
0
0
0°C < T < 10°C
0
1
0
1
10°C < T < 20°C
0
1
1
0
20°C < T < 30°C
0
1
1
1
30°C < T < 40°C
1
0
0
0
40°C < T < 50°C
1
0
0
1
50°C < T < 60°C
1
0
1
0
60°C < T < 70°C
1
0
1
1
70°C < T < 80°C
1
1
0
0
T > 80°C
Table 10.  Temperature Register Contents