A/D CONVERTER
11-8
11
32192/32195/32196 Group Hardware Manual
Rev.1.10 REJ09B0123-0110 Apr.06.07
11.1 Outline of A/D Converter
…
Table 11.1.2 Registers in Which Scan Mode A/D Conversion Results Are Stored
Scan Mode Register 1
Selected channels
A/D conversion result
channel selection
for single-shot scan
for continuous scan
storage register
B'0000:0
ADiIN0
10-bit A/Di Data Register 0
(ADiIN0)
Completed
ADiIN0
10-bit A/Di Data Register 0
(Repeated until
forcibly terminated)
B'0001:1
ADiIN0
10-bit A/Di Data Register 0
(ADiIN1)
ADiIN1
10-bit A/Di Data Register 1
Completed
ADiIN0
10-bit A/Di Data Register 0
(Repeated until
forcibly terminated)
B'0010:2
ADiIN0
10-bit A/Di Data Register 0
(ADiIN2)
ADiIN1
10-bit A/Di Data Register 1
ADiIN2
10-bit A/Di Data Register 2
Completed
ADiIN0
10-bit A/Di Data Register 0
(Repeated until
forcibly terminated)
B'0011:3
ADiIN0
10-bit A/Di Data Register 0
(ADiIN3)
ADiIN1
10-bit A/Di Data Register 1
ADiIN2
10-bit A/Di Data Register 2
ADiIN3
10-bit A/Di Data Register 3
Completed
ADiIN0
10-bit A/Di Data Register 0
(Repeated until
forcibly terminated)
B'XXXX:n
ADiIN0
10-bit A/Di Data Register 0
(ADiINn)
ADiIN1
10-bit A/Di Data Register 1
ADiIN2
10-bit A/Di Data Register 2
n
≤15
...
ADiINn
10-bit A/Di Data Register n
Completed
ADiIN0
10-bit A/Di Data Register 0
(Repeated until
forcibly terminated)
(i=0)