參數(shù)資料
型號: KSZ8851-16MLLJ
廠商: Micrel Inc
文件頁數(shù): 9/90頁
文件大?。?/td> 0K
描述: IC CTLR MAC 1PORT NON-PCI 48LQFP
標準包裝: 250
控制器類型: 以太網(wǎng)控制器,MAC/PHY
接口: 總線
電源電壓: 1.8V,2.5V,3.3V
工作溫度: -40°C ~ 125°C
安裝類型: 表面貼裝
封裝/外殼: 48-LQFP
供應商設備封裝: 48-LQFP(7x7)
包裝: 托盤
其它名稱: 576-3629
KSZ8851-16MLLJ-ND
Micrel, Inc.
KSZ8851-16MLLJ
March 2010
17
M9999-030210-1.0
The KSZ8851-16MLLJ will also assert PME output pin if the corresponding enable bit[8] is set in PMECR (0xD4) register
or generate interrupt to signal an energy detect event occurred if the corresponding enable bit[2] is set in IER (0x90)
register. Once the power management unit detects the PME output asserted or interrupt active, it will power up the host
CPU and issue a wakeup command which is a read cycle to read the Globe Reset Register (GRR at 0x26) to wake up the
KSZ8851-16MLLJ from the low power state to the normal power state in case the auto-wakeup enable bit[7] is disabled.
When KSZ8851-16MLLJ is at normal power state, it is able to transmit or receive packet from the cable.
Soft Power Down Mode
The soft power down mode is entered by setting bit[1:0]=10 in PMECR register. When KSZ8851-16MLLJ is in this mode,
all PLL clocks are disabled, the PHY and the MAC are off, all internal registers value will not change, and the host
interface is only used to wake-up this device from current soft power down mode to normal operation mode.
In order to go back the normal operation mode from this soft power down mode, the only way to leave this mode is
through a host wake-up command which the CPU issues to read the Globe Reset Register (GRR at 0x26).
Power Saving Mode
The power saving mode is entered when auto-negotiation mode is enabled, cable is disconnected, and by setting
bit[1:0]=11 in PMECR register and bit [10]=1 in P1SCLMD register. When KSZ8851M is in this mode, all PLL clocks are
enabled, MAC is on, all internal registers value will not change, and host interface is ready for CPU read or write. In this
mode, it mainly controls the PHY transceiver on or off based on line status to achieve power saving. The PHY remains
transmitting and only turns off the unused receiver block. Once activity resumes due to plugging a cable or attempting by
the far end to establish link, the KSZ8851M can automatically enabled the PHY power up to normal power state from
power saving mode.
During this power saving mode, the host CPU can program the bit[1:0] in PMECR register and set bit[10]=0 in P1SCLMD
register to transit the current power saving mode to any one of the other three power management operation modes.
Wake-on-LAN
Wake-up frame events are used to wake the system whenever meaningful data is presented to the system over the
network. Examples of meaningful data include the reception of a Magic Packet, a management request from a remote
administrator, or simply network traffic directly targeted to the local system. In all of these instances, the network device is
pre-programmed by the policy owner or other software with information on how to identify wake frames from other network
traffic. The KSZ8851-16MLLJ controller can be programmed to notify the host of the wake-up frame detection with the
assertion of the interrupt signal (INTRN) or assertion of the power management event signal (PME).
A wake-up event is a request for hardware and/or software external to the network device to put the system into a
powered state (working).
A wake-up signal is caused by:
1. Detection of energy signal over a pre-configured value (bit 2 in ISR register)
2. Detection of a linkup in the network link state (bit 3 in ISR register)
3. Receipt of a Magic Packet (bit 4 in ISR register)
4. Receipt of a network wake-up frame (bit 5 in ISR register)
There are also other types of wake-up events that are not listed here as manufacturers may choose to implement these in
their own way.
Detection of Energy
The energy is detected from the cable and is continuously presented for a time longer than pre-configured value,
especially when this energy change may impact the level at which the system should re-enter to the normal power state.
Detection of Linkup
Link status wake events are useful to indicate a linkup in the network’s connectivity status.
相關(guān)PDF資料
PDF描述
KSZ8851-32MQLI IC CTLR MAC/PHY NON PCI 128PQFP
KSZ8851-32MQL IC CTLR MAC/PHY NON PCI 128PQFP
KSZ8851SNLI TR IC ETHERNET CTLR 1PORT PCI 32MLF
KSZ8862-16MQL IC SWITCH 10/100 16BIT 128-PQFP
KSZ8862-32MQL IC ETHERNET SW 2PORT BUS 128PQFP
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
KSZ8851-16MLLJ_10 制造商:MICREL 制造商全稱:Micrel Semiconductor 功能描述:Single-Port Ethernet MAC Controller with 8-Bit or 16-Bit Non-PCI Interface
KSZ8851-16MLLU 功能描述:以太網(wǎng) IC Single-Port Ethernet Controller (Automotive Grade) RoHS:否 制造商:Micrel 產(chǎn)品:Ethernet Switches 收發(fā)器數(shù)量:2 數(shù)據(jù)速率:10 Mb/s, 100 Mb/s 電源電壓-最大:1.25 V, 3.45 V 電源電壓-最小:1.15 V, 3.15 V 最大工作溫度:+ 85 C 封裝 / 箱體:QFN-64 封裝:Tray
KSZ8851-16MLLU TR 功能描述:以太網(wǎng) IC Single-Port Ethernet Controller (Automotive Grade) RoHS:否 制造商:Micrel 產(chǎn)品:Ethernet Switches 收發(fā)器數(shù)量:2 數(shù)據(jù)速率:10 Mb/s, 100 Mb/s 電源電壓-最大:1.25 V, 3.45 V 電源電壓-最小:1.15 V, 3.15 V 最大工作溫度:+ 85 C 封裝 / 箱體:QFN-64 封裝:Tray
KSZ8851-16MQL 功能描述:以太網(wǎng) IC Single Ethernet Port + Generic (16-bit) Bus Interface(Lead Free) RoHS:否 制造商:Micrel 產(chǎn)品:Ethernet Switches 收發(fā)器數(shù)量:2 數(shù)據(jù)速率:10 Mb/s, 100 Mb/s 電源電壓-最大:1.25 V, 3.45 V 電源電壓-最小:1.15 V, 3.15 V 最大工作溫度:+ 85 C 封裝 / 箱體:QFN-64 封裝:Tray
KSZ8851-16MQL-EVAL 功能描述:以太網(wǎng)開發(fā)工具 Single Ethernet Port + Generic (16-bit) Bus Interface(Lead Free) Eval Board RoHS:否 制造商:Micrel 產(chǎn)品:Evaluation Boards 類型:Ethernet Transceivers 工具用于評估:KSZ8873RLL 接口類型:RMII 工作電源電壓: