8/01/00
Am79C976
183
P R E L I M I N A R Y
is not affected by S_RESET or
setting the STOP bit.
6
MAPINTE
MII Auto-Poll Interrupt Enable. If
MAPINTE is set, the MAPINT bit
will be able to set the INTR bit.
Read/Write accessible. MAP-
INTE is set to 0 by H_RESET and
is not affected by S_RESET or
setting the STOP bit
5
MCCINT
MII
Complete Interrupt. The MII Man-
agement Command Complete In-
terrupt is set by the Am79C976
controller when a read or write
operation to the MII Data Port
(BCR34) is complete.
Management
Command
When MCCINT is set to 1, INTA
is asserted if the enable bit
MCCINTE is set to 1.
Read/Write accessible. MCCINT
is cleared by the host by writing a
1. Writing a 0 has no effect.
MCCINT is cleared by H_RESET
and is not affected by S_RESET
or setting the STOP bit.
4
MCCINTE
MII
Complete Interrupt Enable. If
MCCINTE is set to 1, the
MCCINT bit will be able to set the
INTR bit when the host reads or
writes to the MII Data Port
(BCR34) only. Internal MII Man-
agement Commands will not gen-
erate an interrupt. For instance,
Auto-Poll state machine generat-
ed MII management frames will
not generate an interrupt upon
completion unless there is a com-
pare error which gets reported
through the MAPINT (CSR7, bit
6) interrupt or the MCCIINTE is
set to 1.
Management
Command
Read/Write
CINTE is set to 0 by H_RESET
and is not affected by S_RESET
or setting the STOP bit.
accessible.
MC-
3
MCCIINT
MII
Complete Internal Interrupt. The
MII
Management
Complete Interrupt is set by the
Am79C976 controller when a
Management
Command
Command
read or write operation on the MII
management port is complete
from an internal operation. Exam-
ples of internal operations are
Auto-Poll or MII Management
Port generated MII management
frames. These are normally hid-
den to the host.
When MCCIINT is set to 1, INTA
is asserted if the enable bit
MCCINTE is set to 1.
Read/Write accessible. MCCIINT
is cleared by the host by writing a
1. Writing a 0 has no effect.
MCCIINT
is
H_RESET and is not affected by
S_RESET or setting the STOP
bit.
cleared
by
2
MCCIINTE
MII
Complete Internal Interrupt En-
able. If MCCIINTE is set to 1, the
MCCIINT bit will be able to set
the INTR bit when the internal
state machines generate MII
management frames. For in-
stance, when MCCIINTE is set to
1 and the Auto-Poll state ma-
chine generates a MII manage-
ment frame, the MCCIINT will set
the INTR bit upon completion of
the MII management frame re-
gardless of the comparison out-
come.
Management
Command
Read/Write
MCCIINTE is set to 0 by
H_RESET and is not affected by
S_RESET or setting the STOP
bit.
accessible.
1
MIIPDTINT MII PHY Detect Transition Inter-
rupt. The MII PHY Detect Transi-
tion Interrupt is set by the
Am79C976 controller whenever
the MIIPD bit (BCR32, bit 14)
transitions from 0 to 1 or vice ver-
sa.
Read/Write accessible. MIIP-
DTINT is cleared by the host by
writing a 1. Writing a 0 has no ef-
fect. MIIPDTINT is cleared by
H_RESET and is not affected by
S_RESET or setting the STOP
bit.