![](http://datasheet.mmic.net.cn/Analog-Devices-Inc/AD571JD_datasheet_100246/AD571JD_2.png)
AD571–SPECIFICATIONS
(TA = +25 C, V+ = +5 V, V– = –12 V or –15 V, all voltages measured with respect to
digital common, unless otherwise noted)
REV.
–2–
AD571J
AD571K
AD571S
Model
Min
Typ
Max
Min
Typ
Max
Min
Typ
Max
Units
RESOLUTION
10
Bits
RELATIVE ACCURACY, TA
1
1/2
1
LSB
TMIN to TMAX
1
1/2
1
LSB
FULL-SCALE CALIBRATION
±2
LSB
UNIPOLAR OFFSET
1
1/2
1
LSB
BIPOLAR OFFSET
1
1/2
1
LSB
DIFFERENTIAL NONLINEAIRTY, TA
10
Bits
TMIN to TMAX
910
10
Bits
TEMPERATURE RANGE
0
+70
0
+70
–55
+125
°C
TEMPERATURE COEFFICIENTS
Unipolar Offset
2
1
2
LSB
Bipolar Offset
2
1
2
LSB
Full-Scale Calibration2
4
2
LSB
POWER SUPPLY REJECTION
CMOS Positive Supply
+13.5 V
≤ V + ≤ +16.5 V
–
1
–
LSB
TTL Positive Supply
+4.5 V
≤ V + ≤ +5.5 V
2
1
2
LSB
Negative Supply
–16.0 V
≤ V – ≤ –13.5 V
2
1
2
LSB
ANALOG INPUT IMPEDANCE
3.0
5.0
7.0
3.0
5.0
7.0
3.0
5.0
7.0
k
Ω
ANALOG INPUT RANGES
Unipolar
0
+10
0
+10
0
+10
V
Bipolar
–5
+5
–5
+5
–5
+5
V
OUTPUT CODING
Unipolar
Positive True Binary
Bipolar
Positive True Offset Binary
LOGIC OUTPUT
Output Sink Current
(VOUT = 0.4 V max, TMIN to TMAX)
3.2
mA
Output Source Current
1
(VOUT = 2.4 V max, TMIN to TMAX)
0.5
mA
Output Leakage
40
μA
LOGIC INPUT
Input Current
100
μA
Logic “1”
2.0
V
Logic “0”
0.8
V
CONVERSION TIME, TMIN to TMAX
15
25
40
15
25
40
15
25
40
μs
POWER SUPPLY
V+
+4.5
+5.0
+7.0
+4.5
+5.0
+16.5
+4.5
+5.0
+7.0
V
V–
–12.0
–15
–16.5
–12.0
–15
–16.5
–12.0
–15
–16.5
V
OPERATING CURRENT
V+
7
mA
V–
9
15
9
15
9
15
mA
PACKAGE OPTION
2
Ceramic DIP (D-18)
AD571JD
AD571KD
AD571SD
NOTES
1The data output lines have active pull-ups to source 0.5 mA. The
DATA READY line is open collector with a nominal 6 kΩ internal pull-up resistor.
2For details on grade and package offerings for SD-grade in accordance with MIL-STD-883, refer to Analog Devices’ Military Products databook or current /883B
data sheet.
Specifications subject to change without notice.
Specifications shown in boldface are tested on all production units at final electrical test. Results from those tests are used to calculate outgoing quality levels. All min
and max specifications are guaranteed, although only those shown in boldface are tested on all production units.
B
15
8
15