參數(shù)資料
型號: XRT75R12DIB
廠商: Exar Corporation
文件頁數(shù): 57/133頁
文件大?。?/td> 0K
描述: IC LIU E3/DS3/STS-1 12CH 420TBGA
標準包裝: 40
類型: 線路接口裝置(LIU)
驅動器/接收器數(shù): 12/12
規(guī)程: DS3,E3,STS-1
電源電壓: 3.135 V ~ 3.465 V
安裝類型: 表面貼裝
封裝/外殼: 420-LBGA 裸露焊盤
供應商設備封裝: 420-TBGA(35x35)
包裝: 托盤
XRT75R12D
I
REV. 1.0.3
TWELVE CHANNEL E3/DS3/STS-1 LINE INTERFACE UNIT WITH SONET DESYNCHRONIZER
TABLE OF CONTENTS
GENERAL DESCRIPTION.............................................................................................................. 1
APPLICATIONS ............................................................................................................................................................... 1
FIGURE 1. BLOCK DIAGRAM OF THE XRT 75R12D.................................................................................................................................. 1
ORDERING INFORMATION .................................................................................................................... 1
FEATURES..................................................................................................................................................................... 2
TRANSMIT INTERFACE CHARACTERISTICS ....................................................................................................................... 2
RECEIVE INTERFACE CHARACTERISTICS ......................................................................................................................... 2
PIN DESCRIPTIONS (BY FUNCTION) ........................................................................................... 3
SYSTEM-SIDE TRANSMIT INPUT AND TRANSMIT CONTROL PINS....................................................................................... 3
SYSTEM-SIDE RECEIVE OUTPUT AND RECEIVE CONTROL PINS ....................................................................................... 6
RECEIVE LINE SIDE PINS ............................................................................................................................................... 8
CLOCK INTERFACE......................................................................................................................................................... 9
GENERAL CONTROL PINS ............................................................................................................................................ 10
POWER SUPPLY PINS .................................................................................................................................................. 12
GROUND PINS ............................................................................................................................................................. 13
TABLE 1: LIST BY PIN NUMBER ............................................................................................................................................................. 14
FUNCTIONAL DESCRIPTION ...................................................................................................... 18
1.0 R3 TECHNOLOGY (RECONFIGURABLE, RELAYLESS REDUNDANCY) ....................................... 18
1.1 NETWORK ARCHITECTURE ......................................................................................................................... 18
FIGURE 2. NETWORK REDUNDANCY ARCHITECTURE .............................................................................................................................. 18
2.0 CLOCK SYNTHESIZER ....................................................................................................................... 19
FIGURE 3. SIMPLIFIED BLOCK DIAGRAM OF THE INPUT CLOCK CIRCUITRY DRIVING THE MICROPROCESSOR ............................................ 19
TABLE 2: REFERENCE CLOCK PERFORMANCE SPECIFICATIONS.............................................................................................................. 19
2.1 CLOCK DISTRIBUTION ................................................................................................................................. 20
FIGURE 4. CLOCK DISTRIBUTION CONGIFURED IN E3 MODE WITHOUT USING SFM ................................................................................ 20
3.0 THE RECEIVER SECTION .................................................................................................................. 21
FIGURE 5. RECEIVE PATH BLOCK DIAGRAM .......................................................................................................................................... 21
3.1 RECEIVE LINE INTERFACE .......................................................................................................................... 21
FIGURE 6. RECEIVE LINE INTERFACECONNECTION................................................................................................................................. 21
3.2 ADAPTIVE GAIN CONTROL (AGC) .............................................................................................................. 21
3.3 RECEIVE EQUALIZER ................................................................................................................................... 22
FIGURE 7. ACG/EQUALIZER BLOCK DIAGRAM ....................................................................................................................................... 22
3.3.1 RECOMMENDATIONS FOR EQUALIZER SETTINGS .............................................................................................. 22
3.4 CLOCK AND DATA RECOVERY ................................................................................................................... 22
3.4.1 DATA/CLOCK RECOVERY MODE ............................................................................................................................ 22
3.4.2 TRAINING MODE........................................................................................................................................................ 22
3.5 LOS (LOSS OF SIGNAL) DETECTOR ........................................................................................................... 23
3.5.1 DS3/STS-1 LOS CONDITION ..................................................................................................................................... 23
TABLE 3: THE ALOS (ANALOG LOS) DECLARATION AND CLEARANCE THRESHOLDS FOR A GIVEN SETTING OF REQEN (DS3 AND STS-1 AP-
PLICATIONS
).......................................................................................................................................................................... 23
3.5.2 DISABLING ALOS/DLOS DETECTION ..................................................................................................................... 23
3.5.3 E3 LOS CONDITION:.................................................................................................................................................. 23
FIGURE 8. LOSS OF SIGNAL DEFINITION FOR E3 AS PER ITU-T G.775 .................................................................................................. 23
FIGURE 9. LOSS OF SIGNAL DEFINITION FOR E3 AS PER ITU-T G.775................................................................................................... 24
3.5.4 INTERFERENCE TOLERANCE.................................................................................................................................. 24
FIGURE 10. INTERFERENCE MARGIN TEST SET UP FOR DS3/STS-1 ...................................................................................................... 24
FIGURE 11. INTERFERENCE MARGIN TEST SET UP FOR E3. ................................................................................................................... 24
TABLE 4: INTERFERENCE MARGIN TEST RESULTS ................................................................................................................................. 25
3.5.5 MUTING THE RECOVERED DATA WITH LOS CONDITION:................................................................................... 26
FIGURE 12. RECEIVER DATA OUTPUT AND CODE VIOLATION TIMING ........................................................................................................ 26
3.6 B3ZS/HDB3 DECODER .................................................................................................................................. 26
4.0 JITTER ................................................................................................................................................. 27
4.1 JITTER TOLERANCE ..................................................................................................................................... 27
FIGURE 13. JITTER TOLERANCE MEASUREMENTS .................................................................................................................................. 27
4.1.1 DS3/STS-1 JITTER TOLERANCE REQUIREMENTS ................................................................................................ 27
FIGURE 14. INPUT JITTER TOLERANCE FOR DS3/STS-1 ...................................................................................................................... 28
4.1.2 E3 JITTER TOLERANCE REQUIREMENTS.............................................................................................................. 28
FIGURE 15. INPUT JITTER TOLERANCE FOR E3 .................................................................................................................................... 28
TABLE 5: JITTER AMPLITUDE VERSUS MODULATION FREQUENCY (JITTER TOLERANCE) ........................................................................... 29
4.2 JITTER TRANSFER ........................................................................................................................................ 29
相關PDF資料
PDF描述
XRT75R12IB IC LIU E3/DS3/STS-1 12CH 420TBGA
ISL267450AIUZ-T IC INTERFACE
MS3116P16-8P CONN PLUG 8POS STRAIGHT W/PINS
IDT72V815L15PFI IC FIFO SYNC 512X18 15NS 128QFP
MS27513E8F35SD CONN RCPT 6POS BOX MNT W/SCKT
相關代理商/技術參數(shù)
參數(shù)描述
XRT75R12DIB-F 功能描述:網(wǎng)絡控制器與處理器 IC 12 Channel 3.3V-5V temp -45 to 85C RoHS:否 制造商:Micrel 產(chǎn)品:Controller Area Network (CAN) 收發(fā)器數(shù)量: 數(shù)據(jù)速率: 電源電流(最大值):595 mA 最大工作溫度:+ 85 C 安裝風格:SMD/SMT 封裝 / 箱體:PBGA-400 封裝:Tray
XRT75R12DIB-L 功能描述:LIN 收發(fā)器 Synch RoHS:否 制造商:NXP Semiconductors 工作電源電壓: 電源電流: 最大工作溫度: 封裝 / 箱體:SO-8
XRT75R12ES 功能描述:時鐘合成器/抖動清除器 12CH T3/E3/STS1LIUJA 3.3V W/REDUNDANCY RoHS:否 制造商:Skyworks Solutions, Inc. 輸出端數(shù)量: 輸出電平: 最大輸出頻率: 輸入電平: 最大輸入頻率:6.1 GHz 電源電壓-最大:3.3 V 電源電壓-最小:2.7 V 封裝 / 箱體:TSSOP-28 封裝:Reel
XRT75R12IB 功能描述:外圍驅動器與原件 - PCI 12CH E3/DS3/STS W/JITTER R3 TECH RoHS:否 制造商:PLX Technology 工作電源電壓: 最大工作溫度: 安裝風格:SMD/SMT 封裝 / 箱體:FCBGA-1156 封裝:Tray
XRT75R12IB-F 功能描述:外圍驅動器與原件 - PCI 12 Channel 3.3V-5V temp -45 to 85C RoHS:否 制造商:PLX Technology 工作電源電壓: 最大工作溫度: 安裝風格:SMD/SMT 封裝 / 箱體:FCBGA-1156 封裝:Tray