Ericsson Internal
PRODUCT SPECIFICATION
25 (39)
Prepared (also subject responsible if other)
No.
EJANLLI
2/1301-BMR 657 5818 Uen
Approved
Checked
Date
Rev
Reference
SEC/D (Betty Wu)
EQUENXU
2009-12-02
C
2.5V, 16A / 40.0W Electrical Specification
PMP 5818UW P
Tref = -40 to +85C, VI = 4.5 to 14 V, Radj = 2.38 kΩ, unless otherwise specified under Conditions.
Typical values given at: Tref = +25°C, VI= 5/12 V, max IO , unless otherwise specified under Conditions.
Additional Cin = 330+22 F and Cout = 220 F. See Operating Information section for selection of capacitor types.
Connect the sense pin, where available, to the output pin.
Characteristics
Conditions
min
typ
max
Unit
VI
Input voltage range
4.5
5/12
14
V
VIoff
Turn-off input voltage
Decreasing input voltage
3.9
4.1
V
VIon
Turn-on input voltage
Increasing input voltage
4.3
4.4
V
CI
Internal input capacitance
44
μ
F
PO
Output power
0
33
W
VI = 5 V, 50 % of max IO
94.2
VI = 5 V
VI = 5 V, max IO
91.9
VI = 12 V, 50 % of max IO
90.2
η
Efficiency
VI = 12 V
VI = 12 V, max IO
89.4
%
VI = 5 V, max IO
3.6
4.1
W
Pd
Power Dissipation
VI = 12 V, max IO
4.8
5.3
W
VI = 5 V, IO= 0 A
0.34
W
Pli
Input idling power
VI = 12 V, IO= 0 A
0.99
W
VI = 5 V (turned off with RC)
4.7
mW
PRC
Input standby power
VI = 12 V (turned off with RC)
26.4
mW
VI = 5 V, max IO
8.8
A
IS
Static Input current
VI = 12 V, max IO
3.8
A
fs
Switching frequency
0-100 % of max IO
270
300
330
kHz
VOi
Output voltage initial setting
and accuracy
Tref = +25°C, VI = 5/12 V, max IO
2.462
2.500
2.538
V
Output voltage tolerance band
10-100 % of max IO
2.425
2.575
V
VI = 5 V, IO = 0 A
2.501
V
Idling voltage
VI = 12 V, IO = 0 A
2.503
Line regulation
max IO
±3
mV
VO
Load regulation
VI = 5/12 V, 0-100 % of max IO
±2
mV
Vtr
Load transient
voltage deviation
±75
mV
ttr
Load transient recovery time
VI = 5 V, Load step 25-75-25 % of
max IO, di/dt = 2.5 A/μs
Without Turbo Trans
Co =1640 F Type C
40
μ
s
Vtr
Load transient
voltage deviation
±40
mV
ttr
Load transient recovery time
VI = 5 V, Load step 25-75-25 % of
max IO, di/dt = 2.5 A/μs
With Turbo Trans
Co =1640 F Type C; RTT =2 kΩ
30
μ
s
Vtr
Load transient
voltage deviation
±70
mV
ttr
Load transient recovery time
VI = 12 V, Load step 25-75-25 % of
max IO, di/dt = 2.5 A/μs
Without Turbo Trans
30
μ
s
E
PMP 5000 series
PoL Regulator
Input 4.5 - 14 V, Output up to 16 A / 88 W
EN/LZT 146 388 R1B December 2009
Ericsson AB
Technical Specication
28