MT9044
13
MT9044 Measures of Performance
The following are some synchronizer performance
indicators and their corresponding definitions.
Intrinsic Jitter
Intrinsic
synchronizing circuit and is measured at its output. It
is measured by applying a reference signal with no
jitter to the input of the device, and measuring its
output jitter. Intrinsic jitter may also be measured
when the device is in a non-synchronizing mode,
such as free running or holdover, by measuring the
output jitter of the device. Intrinsic jitter is usually
measured with various bandlimiting filters depending
on the applicable standards.
jitter
is
the
jitter
produced
by
the
Jitter Tolerance
Jitter tolerance is a measure of the ability of a PLL to
operate properly (i.e., remain in lock and or regain
lock in the presence of large jitter magnitudes at
various jitter frequencies) when jitter is applied to its
reference. The applied jitter magnitude and jitter
frequency depends on the applicable standards.
Jitter Transfer
Jitter transfer or jitter attenuation refers to the
magnitude of jitter at the output of a device for a
given amount of jitter at the input of the device. Input
jitter
is
applied
at
various
frequencies, and output jitter is measured with
various
filters
depending
standards.
amplitudes
and
on
the
applicable
For the MT9044, two internal elements determine
the jitter attenuation. This includes the internal 1.9Hz
low pass loop filter and the phase slope limiter. The
phase slope limiter limits the output phase slope to
5ns/125us. Therefore, if the input signal exceeds this
rate, such as for very large amplitude low frequency
input jitter, the maximum output phase slope will be
limited (i.e. attenuated) to 5ns/125us.
The MT9044 has thirteen outputs with three possible
input frequencies for a total of 39 possible jitter
transfer functions. However, the data sheet section
on AC Electrical Characteristics - Jitter Transfer
specifies transfer values for only three cases, 8kHz
to 8kHz, 1.544MHz to 1.544MHz and 2.048MHz to
2.048MHz. Since all outputs are derived from the
same signal, these transfer values apply to all
outputs.
It should be noted that 1UI at 1.544MHz is 644ns,
which is not equal to 1UI at 2.048MHz, which is
488ns. Consequently, a transfer value using different
input and output frequencies must be calculated in
common units (e.g. seconds) as shown in the
following example.
What is the T1 and E1 output jitter when the T1 input
jitter is 20UI (T1 UI Units) and the T1 to T1 jitter
attenuation is 18dB
Using the above method, the jitter attenuation can be
calculated for all combinations of inputs and outputs
based on the three jitter transfer functions provided.
Note that the resulting jitter transfer functions for all
combinations of inputs (8kHz, 1.544MHz, 2.048MHz)
and
outputs
(8kHz,
4.096MHz, 8.192MHz, 16.384MHz) for a given input
signal (jitter frequency and jitter amplitude) are the
same.
1.544MHz,
2.048MHz,
Since
attenuation will appear to be lower for small input
jitter signals than for large ones. Consequently,
accurate jitter transfer function measurements are
usually made with large input jitter signals (e.g. 75%
of the specified maximum jitter tolerance).
intrinsic
jitter
is
always
present,
jitter
Frequency Accuracy
Frequency accuracy is defined as the absolute
tolerance of an output clock signal when it is not
locked to an external reference, but is operating in a
free running mode. For the MT9044, the Freerun
accuracy is equal to the Master Clock (OSCi)
accuracy.
Holdover Accuracy
Holdover
tolerance of an output clock signal, when it is not
locked to an external reference signal, but is
operating using storage techniques. For the MT9044,
accuracy
is
defined
as
the
absolute
OutputT
1
InputT
1
A
–
20
------
×
10
18
20
=
OutputT
1
20
–
×
10
2.5
UI T
1
)
=
=
OutputE
1
OutputT
1
ns
488
ns
)
)
-644
3.3
UI T
1
)
=
×
=
OutputE
1
OutputT
1
UIT
1
1
UIE
1
)
)
-1
×
=