2: 1386SHOW
3-22
EPSON
S1D13806 SERIES UTILITIES (X28B-B-002-01)
2.7 Program Messages
ERROR: Could not detect S1D13806.
The ID register did not indicate the presence of the 13806.
ERROR: Could not map memory from evaluation board to host platform.
This message should only be shown for DOS platforms. In this case the DOS extender could not be
initialized, or was unable to get the linear address of the display buffer.
ERROR: In the given display surface configuration, the user must select the same BPP for both
LCD and CRT/TV.
When two displays are using an image from the same display memory block, both displays must be
configured for the same color depth (bpp).
ERROR: Invalid display surface number.
The "ds=" command line option included an invalid value. The parameter "ds=?" lists the valid
numbers.
WARNING: LCD and CRT resolutions not same but use same display memory block.
LCD: (width, height)
CRT: (width, height)
When the LCD and CRT are displaying an image from the same display memory block, the higher
resolution device displays the entire image and the lower resolution device displays a portion of the
image using a virtual display.
WARNING: LCD and TV resolutions not same but use same display memory block.
LCD: (width, height)
TV: (width, height)
When the LCD and TV are displaying an image from the same display memory block, the higher
resolution device displays the entire image and the lower resolution device displays a portion of the
image using a virtual display.
ERROR: LCD must be in landscape mode.
The LCD panel must be configured for SwivelView 0° mode (landscape) when using display surfaces
3 and 4 (both the LCD display and CRT/TV are active using the same memory block).
ERROR: Not enough display buffer memory.
There was insufficient display buffer for the given configuration. Memory requirements depend on:
the display resolution(s).
the bit-per-pixel depth(s).
whether a Dual Panel Buffer is required.
the number of displays active (LCD or LCD and CRT/TV).
WARNING: Cannot use 4 bpp LCD in SwivelView 90° or SwivelView 270° modes.
A color depth of 4 bpp is not supported in SwivelView 90° or SwivelView 270° modes.
ERROR: Do not select 4 bpp LCD in SwivelView 90° or SwivelView 270°.
The “bl=” option selected a color depth not supported with SwivelView enabled.