參數(shù)資料
型號(hào): EDX5116ADSE-4D-E
廠商: ELPIDA MEMORY INC
元件分類: DRAM
英文描述: 512M bits XDR⑩ DRAM
中文描述: 32M X 16 RAMBUS, PBGA104
封裝: ROHS COMPLIANT, FBGA-104
文件頁數(shù): 13/78頁
文件大?。?/td> 3311K
代理商: EDX5116ADSE-4D-E
Data Sheet E1033E30 (Ver. 3.0)
13
EDX5116ADSE
refresh row (12 bits in all) are implemented in the REFr regis-
ters
the rest are reserved. Note also that the RA2..0 field that
specifies the refresh bank address is also referred to as BR2..0.
See “Refresh Transactions” on page 40.
Table 5 shows the POP field encoding in the ROWP packet.
The first encoding specifies a NOPP (no operation) command.
There are four variations of PRE (precharge) command. Each
uses the BP field to specify the bank to be precharged. Each
also specifies a different delay of up to 3*t
CYCLE
using the
POP[1:0] field. A precharge command may be specified in
addition to a refresh command using the ROP field.
Table 6 shows the XOP field encoding in the COLX packet.
This field encodes the remaining commands.
The CALC and CALE commands perform calibration opera-
tions to ensure signal integrity on the Channel. See “Calibra-
tion Transactions” on page 42.
The PDN command causes the device to enter a power-down
state. See “Power State Management” on page 44.
Table 5
POP Field Encoding Summary
POP
[2:0]
Command
Description
000
NOPP
No operation.
001
-
Reserved.
010
-
Reserved.
011
-
Reserved.
100
PRE0
Row precharge command — Bank BP2..0 is precharged. This command is delayed by 0*t
CYCLE
.
101
PRE1
Row precharge command — Bank BP2..0 is precharged. This command is delayed by 1*t
CYCLE
.
110
PRE2
Row precharge command — Bank BP2..0 is precharged. This command is delayed by 2*t
CYCLE
.
111
PRE3
Row precharge command — Bank BP2..0 is precharged. This command is delayed by 3*t
CYCLE
.
Table 6
XOP Field Encoding Summary
XOP
[3:0]
Command
Command and Description
XOP
[3:0]
Command
Command and Description
0000
-
Reserved.
1000
CALC
Current calibration command.
0001
-
Reserved.
1001
CALZ
Impedance calibration command.
0010
-
Reserved.
1010
CALE
End calibration command (CALC).
0011
-
Reserved.
1011
-
Reserved.
0100
-
Reserved.
1100
PDN
Enter powerdown power state.
0101
-
Reserved.
1101
-
Reserved.
0110
-
Reserved.
1110
-
Reserved.
0111
-
Reserved.
1111
-
Reserved.
相關(guān)PDF資料
PDF描述
EDX5116ADSE-3A-E 512M bits XDR⑩ DRAM
EDZ20B Low Current Operation at 250 ,Low Reverse Leakage,Low Noise Zener Diode
EDZ22B LED 5MM 563NM HI GRN WATER CLEAR
EDZ24B Low Current Operation at 250 ,Low Reverse Leakage,Low Noise Zener Diode
EDZ Low Current Operation at 250 ,Low Reverse Leakage,Low Noise Zener Diode
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
EDXSPECTRUMDAT/5962R8773901VDA 制造商:Analog Devices 功能描述:SPECTRUM ANALYSIS - Literature
EDXSPECTRUMDATA/F8853801VGA 制造商:Analog Devices 功能描述:DATA - Literature
EDXSPECTRUMDATA/R8512701VZA 制造商:Analog Devices 功能描述:DATA - Literature
EDXSPECTRUMDATA/R9468002VHA 制造商:Analog Devices 功能描述:DATA - Literature
EDXSPECTRUMDATA/R9468002VPA 制造商:Analog Devices 功能描述:DATA - Literature