SCAS604C APRIL 1998 REVISED DECEMBER 2004
4
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, AV
CC
(see Note 1)
Supply voltage range, V
CC
, AV
CC
Input voltage range, V
I
(see Note 2)
Voltage range applied to any output in the high
or low state, V
O
(see Notes 2 and 3)
Input clamp current, I
IK
(V
I
< 0)
Output clamp current, I
OK
(V
O
< 0 or V
O
> V
CC
)
Continuous output current, I
O
(V
O
= 0 to V
CC
)
Continuous current through each V
CC
or GND
Maximum power dissipation at T
A
= 55
°
C (in still air) (see Note 4)
Storage temperature range, T
stg
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. AVCC
must not
exceed VCC.
2. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
3. This value is limited to 4.6 V maximum.
4. The maximum package power dissipation is calculated using a junction temperature of 150
°
C and a board trace length of 750 mils.
For more information, refer to the
Package Thermal Considerations
application note in the
ABT Advanced BiCMOS Technology Data
Book
, literature number SCBD002.
AV
CC
< V
CC
+0.7 V
0.5 V to 4.6 V
0.5 V to 6.5 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0.5 V to V
CC
+ 0.5 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
50 mA
±
50 mA
±
50 mA
±
100 mA
0.7 W
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
65
°
C to 150
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
recommended operating conditions (see Note 5)
MIN
MAX
UNIT
Supply voltage, VCC, AVCC
High-level input voltage, VIH
Low-level input voltage, VIL
Input voltage, VI
High-level output current, IOH
Low-level output current, IOL
Operating free-air temperature, TA
NOTE 5: Unused inputs must be held high or low to prevent them from floating.
3
3.6
V
2
V
0.8
V
0
VCC
12
V
mA
12
mA
°
C
0
70