AD9826
–4–
THERMAL CHARACTERISTICS
Thermal Resistance
28-Lead 5.3 mm SSOP
θJA = 109°C/W
θJC = 39°C/W
ABSOLUTE MAXIMUM RATINGS*
With
Respect
Parameter
To
Min Max
Unit
VIN, CAPT, CAPB
AVSS
–0.3 AVDD + 0.3
V
Digital Inputs
AVSS
–0.3 AVDD + 0.3
V
AVDD
AVSS
–0.5 +6.5
V
DRVDD
DRVSS
–0.5 +6.5
V
AVSS
DRVSS
–0.3 +0.3
V
Digital Outputs
DRVSS
–0.3 DRVDD + 0.3 V
Junction Temperature
150
°C
Storage Temperature
–65
+150
°C
Lead Temperature
300
°C
(10 sec)
*
Stresses above those listed under Absolute Maximum Ratings may cause perma-
nent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those listed in the operational
sections of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability.
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although
the AD9826 features proprietary ESD protection circuitry, permanent damage may occur on devices
subjected to high-energy electrostatic discharges. Therefore, proper ESD precautions are recom-
mended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
REV. B