28F128J3A, 28F640J3A, 28F320J3A
Preliminary
21
Table 16. Status Register Definitions
Table 17. eXtended Status Register Definitions
WSMS
ESS
ECLBS
PSLBS
VPENS
PSS
DPS
R
bit 7
bit 6
bit 5
bit 4
bit 3
bit2
bit 1
bit 0
High Z 
When 
Busy
Status Register Bits
Notes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
SR.7 = WRITE STATE MACHINE STATUS
1 = Ready
0 = Busy
SR.6 = ERASE SUSPEND STATUS
1 = Block Erase Suspended
0 = Block Erase in Progress/Completed
SR.5 = ERASE AND CLEAR LOCK-BITSSTATUS
1 = Error in Block Erasure or Clear Lock-Bits 
0 = Successful Block Erase or Clear Lock-Bits
SR.4 = PROGRAM AND SET LOCK-BIT STATUS
1 = Error in Setting Lock-Bit 
0 = Successful Set Block Lock Bit
SR.3 = PROGRAMMING VOLTAGE STATUS
1 = Low Programming Voltage Detected, Operation
Aborted
0 = Programming Voltage OK
SR.2 =  PROGRAM SUSPEND STATUS
      1  =  Program suspended
      0  =  Program in progress/completed
SR.1 = DEVICE PROTECT STATUS
1 = Block Lock-Bit Detected, Operation Abort
0 = Unlock
SR.0 = RESERVED FOR FUTURE ENHANCEMENTS
Check STS or SR.7 to determine block erase, 
program, or lock-bit configuration completion. SR.6
–
SR.0 are not driven while SR.7 = 
“
0.
”
If both SR.5 and SR.4 are 
“
1
”
s after a block erase or 
lock-bit configuration attempt, an improper 
command sequence was entered.
SR.3 does not provide a continuous programming 
voltage level indication. The WSM interrogates and 
indicates the programming voltage level only after 
Block Erase, Program, Set Block Lock-Bit, or Clear 
Block Lock-Bits command sequences.
SR.1 does not provide a continuous indication of 
block lock-bit values. The WSM interrogates the 
block lock-bits only after Block Erase, Program, or 
Lock-Bit configuration command sequences. It 
informs the system, depending on the attempted 
operation, if the block lock-bit is set. Read the block 
lock configuration codes using the Read Identifier 
Codes command to determine block lock-bit status.
SR.0 is reserved for future use and should be 
masked when polling the status register.
WBS
Reserved
bit 7
bits 6
—
0
High Z 
When 
Busy
Status Register Bits
Notes
No
Yes
XSR.7 = WRITE BUFFER STATUS
1 = Write buffer available
0  = Write buffer not available
XSR.6
–
XSR.0 = RESERVED FOR FUTURE 
ENHANCEMENTS
After a Buffer-Write command, XSR.7 = 1 indicates 
that a Write Buffer is available.
SR.6
–
SR.0 are reserved for future use and should 
be masked when polling the status register.