XStream"燨EM燫F燤odule?燩roduct燤anual爒5.x00燵2006.02.24]?/DIV>
CD (DO3 Configuration) Command
AT Command: ATCD
Binary Command: 0x28 (40 decimal)
Parameter Range: 0 4
Parameter
Configuration
0
RX LED
1
Default high
2
Default low
3
(reserved)
4
Assert only when packet
addressed to module sent
Default Parameter Value: 0
Number of bytes returned: 1
Minimum Firmware Version Required: 4.2B
<Serial Interfacing> CD Command is used to
redefine the behavior of the DO3 (Data Output
3)/RX LED line.
CE (Connection Inactivity Timeout) Command
AT Command: ATCE
Binary Command: 0x34 (52 decimal)
<Networking & Security> Set/Read the duration
of inactivity that will cause a break in a
connection between modules. The base module
will disconnect when no payload has been
transferred for the time specified by the CE
parameter.
Parameter Range:   0 0xFFFF
[x 10 milliseconds]
Default Parameter Value: 0x64 (1d second)
Number of bytes returned: 2
Related Commands: CB ( Connection Duration
Timeout), DC (Disconnect), MD (RF Mode)
Minimum Firmware Version Required: 4.30
CF (Connection Failure Count) Command
AT Command: ATCF
Binary Command: 0x35 (53 decimal)
Parameter Range:   0 0xFFFF
Default Parameter Value: 0
Number of bytes returned: 2
Minimum Firmware Version Required: 4.30
<Diagnostics> Set/Read the number of times the
base module expired retries attempting to send a
Connection Grant Packet. Set to zero to clear the
register.
CL (Last Connection Address) Command
AT Command: ATCL
Binary Command: 0x39 (57 decimal)
Parameter Range:   0 0xFFFF [read-only]
Number of bytes returned: 2
Minimum Firmware Version Required: 4.30
<Diagnostics/Networking & Security> Read the
address of the remote module that last
connected to the base module. A remote module
will return its DT (Destination Address)
parameter.
CM (Connection Message) Command
AT Command: ATCM
Binary Command: 0x38 (56 decimal)
Parameter Range:   0 1
Parameter
Configuration
0
enable
1
disable
Default Parameter Value: 0
Number of bytes returned: 1
Minimum Firmware Version Required: 4.30
<Networking & Security> Select whether base
sends connect messages to the host when a
connection is established. When enabled, a
CONNECTXXXX string is sent to the host of the
base module. XXXX is the MY (Source Address)
of the connected remote module.
牋牘?006燤axStream,營nc.燙onfidential燼nd燩roprietary?/DIV>
22?/DIV>
相關(guān)代理商/技術(shù)參數(shù) |
參數(shù)描述 |
XIB-R |
功能描述:界面模塊 RS-232/485 interface 24XStream 9XCite
RoHS:否 制造商:4D Systems 產(chǎn)品:Serial Converters 通道/端口數(shù)量: 數(shù)據(jù)速率: 接口類型:USB, UART 工作電源電壓:3.3 V, 5 V 最大工作溫度: |
XIB-U |
功能描述:界面模塊 USB interface board 24XStream 9XCite
RoHS:否 制造商:4D Systems 產(chǎn)品:Serial Converters 通道/端口數(shù)量: 數(shù)據(jù)速率: 接口類型:USB, UART 工作電源電壓:3.3 V, 5 V 最大工作溫度: |
XIC25040 |
制造商:XIC 功能描述:25040 24HR '6 |
XILINXPWR-079 |
功能描述:電源管理IC開發(fā)工具 Pow Mgt Eval Mod for Xilinx FPGAs RoHS:否 制造商:Maxim Integrated 產(chǎn)品:Evaluation Kits 類型:Battery Management 工具用于評估:MAX17710GB 輸入電壓: 輸出電壓:1.8 V |
XILINXPWR-080 |
功能描述:電源管理IC開發(fā)工具 Pow Mgt Eval Mod for Xilinx FPGAs RoHS:否 制造商:Maxim Integrated 產(chǎn)品:Evaluation Kits 類型:Battery Management 工具用于評估:MAX17710GB 輸入電壓: 輸出電壓:1.8 V |