參數(shù)資料
型號(hào): XBIB-U
廠商: Digi International/Maxstream
文件頁(yè)數(shù): 35/72頁(yè)
文件大?。?/td> 1116K
描述: BOARD USB ZIGBEE MOD PRO
設(shè)計(jì)資源: XBIB-U Shematic
標(biāo)準(zhǔn)包裝: 1
附件類型: 接口板
適用于相關(guān)產(chǎn)品: XBee 和 XBee Pro 收音機(jī)
XBee/XBeePRO"燨EM燫F燤odules??02.15.4?爒1.xAx燵2007.05.031]
2007燤axStream,營(yíng)nc.
牋牋?5
Chapter??燫F燤odule燙onfiguration
AC (Apply Changes) Command
<AT Command Mode Options> The AC command
is used to explicitly apply changes to module
parameter values. Applying changes means that
the module is re-initialized based on changes
made to its parameter values. Once changes are applied, the module immediately operates
according to the new parameter values.
This behavior is in contrast to issuing the WR (Write) command. The WR command saves parame-
ter values to non-volatile memory, but the module still operates according to previously saved val-
ues until the module is re-booted or the CN (Exit AT Command Mode) command is issued.
Refer to the AT Command - Queue Parameter Value API type for more information.
AI (Association Indication) Command
<Networking {Association}> The AI command is
used to indicate occurrences of errors during the
last association request.
Use the table below to determine meaning of the
returned values.
Returned Value (Hex)
Association Indication
0x00
Successful Completion - Coordinator successfully started or End Device association complete
0x01
Active Scan Timeout
0x02
Active Scan found no PANs
0x03
Active Scan found PAN, but the Coordinator Allow Association bit is not set
0x04
Active Scan found PAN, but Coordinator and End Device are not configured to support beacons
0x05
Active Scan found PAN, but Coordinator ID (PAN ID) value does not match the ID of the End Device
0x06
Active Scan found PAN, but Coordinator CH (Channel) value does not match the CH of the End Device
0x07
Energy Scan Timeout
0x08
Coordinator start request failed
0x09
Coordinator could not start due to Invalid Parameter
0x0A
Coordinator Realignment is in progress
0x0B
Association Request not sent
0x0C
Association Request timed out - no reply was received
0x0D
Association Request had an Invalid Parameter
0x0E
Association Request Channel Access Failure - Request was not transmitted - CCA failure
0x0F
Remote Coordinator did not send an ACK after Association Request was sent
0x10
Remote Coordinator did not reply to the Association Request, but an ACK was received
after sending the request
0x11
[reserved]
0x12
Sync-Loss - Lost synchronization with a Beaconing Coordinator
0x13
Disassociated - No longer associated to Coordinator
0xFF
RF Module is attempting to associate
AT Command: ATAC
Minimum Firmware Version Required: v1.xA0
AT Command: ATAI
Parameter Range: 0 - 0x13 [read-only]
Related Commands: AS (Active Scan), ID (PAN
ID), CH (Channel), ED (Energy Scan), A1 (End
Device Association), A2 (Coordinator
Association), CE (Coordinator Enable)
Minimum Firmware Version Required: v1.x80
相關(guān)PDF資料
PDF描述
XIB-E BOARD INTERFACE ETHERNET
XIB-R BOARD INTERFACE RS232/485
ZMN2400HPDB BOARD ROUTER DEV ZIGBEE 100MW
ZMN24HPDK-B KIT DEV W/ZIGBEE ZMN2400HP
ZNI1000TC IC TEMP SENSOR NI1000 SOT23-3
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
XBIB-U-DEV 功能描述:界面開發(fā)工具 USB XBee-PRO profes onal interface board RoHS:否 制造商:Bourns 產(chǎn)品:Evaluation Boards 類型:RS-485 工具用于評(píng)估:ADM3485E 接口類型:RS-485 工作電源電壓:3.3 V
XBIB-U-SP 功能描述:界面開發(fā)工具 USB/Xbee/Xbee-Pro Inf Brd SMT Pads RoHS:否 制造商:Bourns 產(chǎn)品:Evaluation Boards 類型:RS-485 工具用于評(píng)估:ADM3485E 接口類型:RS-485 工作電源電壓:3.3 V
XBIB-U-SS 功能描述:界面開發(fā)工具 USB/Xbee/Xbee-Pro Inf Brd SMT Skt RoHS:否 制造商:Bourns 產(chǎn)品:Evaluation Boards 類型:RS-485 工具用于評(píng)估:ADM3485E 接口類型:RS-485 工作電源電壓:3.3 V
XBL6450BYFVR 制造商:Texas Instruments 功能描述:ECS BLUELINK - Tape and Reel
XBL6450YFHR 制造商:Texas Instruments 功能描述: