www.ti.com
RECOMMENDED OPERATING CONDITIONS
DEVICE ELECTRICAL CHARACTERISTICS
over operating free-air temperature range unless otherwise noted
ELECTRICAL CHARACTERISTICS
over operating free-air temperature range unless otherwise noted
TB3R1, TB3R2
SLLS587B–NOVEMBER 2003–REVISED MAY 2004
MIN
Nom
3.3
MAX UNIT
3.6
5.3
5
85
Supply voltage, V
CC
Bus pin input voltage, V
AI
, V, V
BI
, V, V
CI
, V, V
DI
, V
Magnitude of differential input voltage, |V
AI
- V|, |V
BI
- V|, |V
CI
- V|, |V
DI
- V|
Operating free-air temperature, T
A
3
V
V
V
°
C
-0.6
(1)
0.1
-40
(1)
The algebraic convention, in which the least positive (most negative) limit is designated as minimum is used in this data sheet, unless
otherwise noted.
PARAMETER
TEST CONDITIONS
Outputs disabled
Outputs enabled
MIN
TYP
MAX
UNIT
mA
mA
34
32
I
CC
Supply current
(1)
(1)
Current is dc power draw as measured through GND pin and does not include power delivered to load.
parameter
test conditions
min
typ
max
unit
V
V
V
V
V
mV
mV
mV
mV
mV
μA
μA
mA
μA
μA
μA
mA
mA
V
OL
V
OH
V
IL
V
IH
V
IK
Output low voltage
Output high voltage
Low level enable input voltage
(1)
High level enable input voltage
(1)
Enable input clamp voltage
V
CC
= 3 V,
V
CC
= 3 V,
V
CC
= 3.6 V
V
CC
= 3.6 V
V
CC
= 3 V,
I
OL
= 8 mA
I
OH
= -400 μA
0.4
2.4
0.8
2
I
I
= -5 mA
TB3R1
TB3R2
(3)
TB3R1
TB3R2
(3)
-1
(2)
100
-50
V
TH+
Positive-going differential input threshold voltage
(1)
, (V
xl
- V)
x = A, B, C, or D
-100
(2)
-200
(2)
V
TH-
Negative-going differential input threshold voltage
(1)
, (V
xl
- V)
x = A, B, C, or D
V
HYST
I
OZL
I
OZH
I
OS
I
IL
Differential input threshold voltage hysteresis, (V
TH+
- V
TH_
)
TB3R1
50
V
O
= 0.4 V
V
O
= 2.4 V
-20
(2)
Output off-state current, (High-Z)
V
CC
= 3.6 V
20
Output short circuit current
(4)
Enable input low current
Enable input high current
Enable input reverse current
Differential input low current
Differential input high current
Output resistance
V
CC
= 3.6 V
V
CC
= 3.6 V,
-100
(2)
-400
(2)
V
IN
= 0.4 V
V
IN
= 2.7 V
V
IN
= 3.6 V
V
IN
= -1.2 V
V
IN
= 5.3 V
20
100
-2
(2)
I
IH
V
CC
= 3.6 V
II
L
I
IH
R
O
V
CC
= 3.6 V,
V
CC
= 3.6 V,
1
20
(1)
(2)
The input levels and difference voltage provide no noise immunity and should be tested only in a static, noise-free environment.
This parameter is listed using a magnitude and polarity/direction convention, rather than an algebraic convention, to match the original
Agere data sheet.
Outputs of unused receivers assume a logic 1 level when the inputs are left open. (It is recomended that all unused positive inputs be
tied to the positive power supply. No external series resistor is required.)
Test must be performed one lead at a time to prevent damage to the device.
(3)
(4)
3