Lucent Technologies Inc. reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application. No
rights under any patent accompany the sale of any such product(s) or information.
Copyright 2000 Lucent Technologies Inc.
All Rights Reserved
September 2000
MN00-082ALC (Replaces MN00-015ALC)
For additional information, contact your Microelectronics Group Account Manager or the following:
INTERNET:
http://www.lucent.com/micro
E-MAIL:
docmaster@micro.lucent.com
N. AMERICA:
Microelectronics Group, Lucent Technologies Inc., 555 Union Boulevard, Room 30L-15P-BA, Allentown, PA 18109-3286
1-800-372-2447
, FAX 610-712-4106 (In CANADA:
1-800-553-2448
, FAX 610-712-4106)
ASIA PACIFIC: Microelectronics Group, Lucent Technologies Singapore Pte. Ltd., 77 Science Park Drive, #03-18 Cintech III, Singapore 118256
Tel. (65) 778 8833
, FAX (65) 777 7495
CHINA:
Microelectronics Group, Lucent Technologies (China) Co., Ltd., A-F2, 23/F, Zao Fong Universe Building, 1800 Zhong Shan Xi Road, Shanghai
200233 P. R. China
Tel. (86) 21 6440 0468
,
ext. 325
, FAX (86) 21 6440 0652
JAPAN:
Microelectronics Group, Lucent Technologies Japan Ltd., 7-18, Higashi-Gotanda 2-chome, Shinagawa-ku, Tokyo 141, Japan
Tel. (81) 3 5421 1600
, FAX (81) 3 5421 1700
EUROPE:
Data Requests: MICROELECTRONICS GROUP DATALINE:
Tel. (44) 7000 582 368
, FAX (44) 1189 328 148
Technical Inquiries: GERMANY:
(49) 89 95086 0
(Munich), UNITED KINGDOM:
(44) 1344 865 900
(Ascot),
FRANCE:
(33) 1 40 83 68 00
(Paris), SWEDEN:
(46) 8 594 607 00
(Stockholm), FINLAND:
(358) 9 3507670
(Helsinki),
ITALY:
(39) 02 6608131
(Milan), SPAIN:
(34) 1 807 1441
(Madrid)
User Manual
September 2000
T8531 and T8531A Tone Processing
Appendix A: ROM Tone Processing Algorithms
(continued)
Subroutine: Initialization Routines
Purpose:
Prepares control and data area for tone processing algorithms.
Name:
tgen_setup, cidg_setup, dtmf_setup
TX or RX:
are called once during system initialization
Address:
0x105A, 0x160E, 0x1B3C
Function:
1. Prepares control area and copy system coefficients from ROM.
Started by:
Main routine
Terminated by:
self
Data Setup Required by this Routine:
Data Storage Locations Altered by this Routine:
Data Name
tgen_ini_table
cidg_ini_table
cidtg_system_coef
dtmf_iir_coef
dtmf_coef_system
tproc_address
Address
0x5EF—0x5F3
0x5F4—0x5FF
0x701—0x70A
0x70B—0x724
0x725—0x754
0x755—0x757
Value
see CPT generation specification
see CID generation specification
transfer rate and out frequency deltas
filters coefficients
system coefficients
RX/TX routine addresses