Chapter 13 FlexRay Communication Controller (FLEXRAY)
MC9S12XF - Family Reference Manual, Rev.1.19
504
Freescale Semiconductor
This register provides conguration, control, and status information related to the generation and access
of the clock sync ID tables and clock sync measurement tables. For a detailed description, see
Table 13-41. SFTCCSR Field Descriptions
Field
Description
15
ELKT
Even Cycle Tables Lock/Unlock Trigger — This trigger bit is used to lock and unlock the even cycle tables.
0 No effect
1 Triggers lock/unlock of the even cycle tables.
14
OLKT
Odd Cycle Tables Lock/Unlock Trigger — This trigger bit is used to lock and unlock the odd cycle tables.
0 No effect
1 Triggers lock/unlock of the odd cycle tables.
13–8
CYCNUM
Cycle Number — This eld provides the number of the cycle in which the currently locked table was
recorded. If none or both tables are locked, this value is related to the even cycle table.
7
ELKS
Even Cycle Tables Lock Status — This status bit indicates whether the application has locked the even
cycle tables.
0 Application has not locked the even cycle tables.
1 Application has locked the even cycle tables.
6
OLKS
Odd Cycle Tables Lock Status — This status bit indicates whether the application has locked the odd cycle
tables.
0 Application has not locked the odd cycle tables.
1 Application has locked the odd cycle tables.
5
EVAL
Even Cycle Tables Valid — This status bit indicates whether the Sync Frame ID and Sync Frame Deviation
Tables for the even cycle are valid. The FlexRay block clears this status bit when it starts updating the tables,
and sets this bit when it has nished the table update.
0 Tables are not valid (update is ongoing)
1 Tables are valid (consistent).
4
OVAL
Odd Cycle Tables Valid — This status bit indicates whether the Sync Frame ID and Sync Frame Deviation
Tables for the odd cycle are valid. The FlexRay block clears this status bit when it starts updating the tables,
and sets this bit when it has nished the table update.
0 Tables are not valid (update is ongoing)
1 Tables are valid (consistent).
2
OPT
One Pair Trigger — This trigger bit controls whether the FlexRay block writes continuously or only one pair
of Sync Frame Tables into the FRM.
If this trigger is set to 1 while SDVEN or SIDEN is set to 1, the FlexRay block writes only one pair of the
enabled Sync Frame Tables corresponding to the next even-odd-cycle pair into the FRM. In this case, the
FlexRay block clears the SDVEN or SIDEN bits immediately.
If this trigger is set to 0 while SDVEN or SIDEN is set to 1, the FlexRay block writes continuously the enabled
Sync Frame Tables into the FRM.
0 Write continuously pairs of enabled Sync Frame Tables into FRM.
1 Write only one pair of enabled Sync Frame Tables into FRM.
1
SDVEN
Sync Frame Deviation Table Enable — This bit controls the generation of the Sync Frame Deviation Tables.
The application must set this bit to request the FlexRay block to write the Sync Frame Deviation Tables into
the FRM.
0 Do not write Sync Frame Deviation Tables
1 Write Sync Frame Deviation Tables into FRM
Note: If SDVEN is set to 1, then SIDEN must also be set to 1.
0
SIDEN
Sync Frame ID Table Enable — This bit controls the generation of the Sync Frame ID Tables. The
application must set this bit to 1 to request the FlexRay block to write the Sync Frame ID Tables into the FRM.
0 Do not write Sync Frame ID Tables
1 Write Sync Frame ID Tables into FRM