參數(shù)資料
型號(hào): MVTX2604AG
廠商: ZARLINK SEMICONDUCTOR INC
元件分類: 網(wǎng)絡(luò)接口
英文描述: Managed 24-Port 10/100 Mb + 2 Port 1 Gb Ethernet Switch
中文描述: DATACOM, LAN SWITCHING CIRCUIT, PBGA553
封裝: 37.50 X 37.50 MM, 2.33 MM HEIGHT, MS-034, HSBGA-553
文件頁(yè)數(shù): 21/173頁(yè)
文件大?。?/td> 2097K
代理商: MVTX2604AG
第1頁(yè)第2頁(yè)第3頁(yè)第4頁(yè)第5頁(yè)第6頁(yè)第7頁(yè)第8頁(yè)第9頁(yè)第10頁(yè)第11頁(yè)第12頁(yè)第13頁(yè)第14頁(yè)第15頁(yè)第16頁(yè)第17頁(yè)第18頁(yè)第19頁(yè)第20頁(yè)當(dāng)前第21頁(yè)第22頁(yè)第23頁(yè)第24頁(yè)第25頁(yè)第26頁(yè)第27頁(yè)第28頁(yè)第29頁(yè)第30頁(yè)第31頁(yè)第32頁(yè)第33頁(yè)第34頁(yè)第35頁(yè)第36頁(yè)第37頁(yè)第38頁(yè)第39頁(yè)第40頁(yè)第41頁(yè)第42頁(yè)第43頁(yè)第44頁(yè)第45頁(yè)第46頁(yè)第47頁(yè)第48頁(yè)第49頁(yè)第50頁(yè)第51頁(yè)第52頁(yè)第53頁(yè)第54頁(yè)第55頁(yè)第56頁(yè)第57頁(yè)第58頁(yè)第59頁(yè)第60頁(yè)第61頁(yè)第62頁(yè)第63頁(yè)第64頁(yè)第65頁(yè)第66頁(yè)第67頁(yè)第68頁(yè)第69頁(yè)第70頁(yè)第71頁(yè)第72頁(yè)第73頁(yè)第74頁(yè)第75頁(yè)第76頁(yè)第77頁(yè)第78頁(yè)第79頁(yè)第80頁(yè)第81頁(yè)第82頁(yè)第83頁(yè)第84頁(yè)第85頁(yè)第86頁(yè)第87頁(yè)第88頁(yè)第89頁(yè)第90頁(yè)第91頁(yè)第92頁(yè)第93頁(yè)第94頁(yè)第95頁(yè)第96頁(yè)第97頁(yè)第98頁(yè)第99頁(yè)第100頁(yè)第101頁(yè)第102頁(yè)第103頁(yè)第104頁(yè)第105頁(yè)第106頁(yè)第107頁(yè)第108頁(yè)第109頁(yè)第110頁(yè)第111頁(yè)第112頁(yè)第113頁(yè)第114頁(yè)第115頁(yè)第116頁(yè)第117頁(yè)第118頁(yè)第119頁(yè)第120頁(yè)第121頁(yè)第122頁(yè)第123頁(yè)第124頁(yè)第125頁(yè)第126頁(yè)第127頁(yè)第128頁(yè)第129頁(yè)第130頁(yè)第131頁(yè)第132頁(yè)第133頁(yè)第134頁(yè)第135頁(yè)第136頁(yè)第137頁(yè)第138頁(yè)第139頁(yè)第140頁(yè)第141頁(yè)第142頁(yè)第143頁(yè)第144頁(yè)第145頁(yè)第146頁(yè)第147頁(yè)第148頁(yè)第149頁(yè)第150頁(yè)第151頁(yè)第152頁(yè)第153頁(yè)第154頁(yè)第155頁(yè)第156頁(yè)第157頁(yè)第158頁(yè)第159頁(yè)第160頁(yè)第161頁(yè)第162頁(yè)第163頁(yè)第164頁(yè)第165頁(yè)第166頁(yè)第167頁(yè)第168頁(yè)第169頁(yè)第170頁(yè)第171頁(yè)第172頁(yè)第173頁(yè)
MVTX2604
Data Sheet
23
Zarlink Semiconductor Inc.
The Transmission DMA (TxDMA) is responsible for multiplexing the data and the address. On a port’s turn, the
TxDMA will move 8 bytes (or up to the EOF) from memory into the port’s associated TxFIFO. After reading the EOF,
the port control requests a FCB release for that frame. The TxDMA arbitrates among multiple buffer release
requests.
The frame is transmitted from the TxFIFO to the line.
3.2 Multicast Data Frame Forwarding
After receiving the switch response, the TxQ manager has to make the dropping decision. A global decision to drop
can be made, based on global FDB utilization and reservations. If so, then the FCB is released and the frame is
dropped. In addition, a selective decision to drop can be made, based on the TxQ occupancy at some subset of
the multicast packet’s destinations. If so, then the frame is dropped at some destinations but not others and the
FCB is not released.
If the frame is not dropped at a particular destination port, then the TxQ manager formats an entry in the multicast
queue for that port and class. Multicast queues are physical queues (unlike the linked lists for unicast frames).
There are 2 multicast queues for each of the 24 10/100 ports. The queue with higher priority has room for 32 entries
and the queue with lower priority has room for 64 entries. There are 4 multicast queues for each of the two Gigabit
ports. The size of the queues are: 32 entries (higher priority queue), 32 entries, 32 entries and 64 entries (lower
priority queue). There is one multicast queue for every two priority classes. For the 10/100 ports to map the 8
transmit priorities into 2 multicast queues, the 2 LSB are discarded. For the gigabit ports to map the 8 transmit
priorities into 4 multicast queues, the LSB are discarded.
During scheduling, the TxQ manager treats the unicast queue and the multicast queue of the same class as one
logical queue. The older head of line of the two queues is forwarded first.
The port control requests a FCB release only after the EOF for the multicast frame has been read by all ports to
which the frame is destined.
3.3 Frame Forwarding To and From CPU
Frame forwarding from the CPU port to a regular transmission port is nearly the same as forwarding between
transmission ports. The only difference is that the physical destination port must be indicated in addition to the
destination MAC address.
Frame forwarding to the CPU port is nearly the same as forwarding to a regular transmission port. The only
difference is in frame scheduling. Instead of using the patent-pending Zarlink Semiconductor scheduling algorithms,
scheduling for the CPU port is simply based on strict priority. That is, a frame in a high priority queue will always be
transmitted before a frame in a lower priority queue. There are four output queues to the CPU and one receive
queue.
4.0 Memory Interface
4.1 Overview
The MVTX2604 provides two 64-bit wide SRAM banks, SRAM Bank A and SRAM Bank B with a 64-bit bus
connected to each. Each DMA can read and write from both bank A and bank B. The following figure provides an
overview of the MVTX2604 SRAM banks.
相關(guān)PDF資料
PDF描述
MVTX2801 Unmanaged 4-Port 1000 Mbps Ethernet Switch
MVTX2801AG Unmanaged 4-Port 1000 Mbps Ethernet Switch
MVTX2802 Managed 4-Port 1000 Mbps Ethernet Switch
MVTX2802AG Managed 4-Port 1000 Mbps Ethernet Switch
MVTX2803 Unmanaged 8-Port 1000 Mbps Ethernet Switch
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
MVTX2801 制造商:ZARLINK 制造商全稱:Zarlink Semiconductor Inc 功能描述:Unmanaged 4-Port 1000 Mbps Ethernet Switch
MVTX2801A 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Unmanaged 4 port Gigabit Ethernet switch
MVTX2801AG 制造商:ZARLINK 制造商全稱:Zarlink Semiconductor Inc 功能描述:Unmanaged 4-Port 1000 Mbps Ethernet Switch
MVTX2802 制造商:ZARLINK 制造商全稱:Zarlink Semiconductor Inc 功能描述:Managed 4-Port 1000 Mbps Ethernet Switch
MVTX2802A 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Managed 4 port Gigabit Ethernet switch