Preliminary Specifications REV.D
Specifications in this manual are tentative and subject to change.
Mitsubishi Microcomputers
M16C/80 group
SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER
Three-phase motor control timers’ functions
112
Three-phase output buffer register 0 (Note)
Symbol
Address
When reset
IDB0
030A16
0016
Bit name
Function
Bit Symbol
W
R
b7
b6 b5
b4
b3
b2
b1
b0
Nothing is assigned.
When write, set "0". When read, its content is "0".
DU0
DUB0
DV0
DW0
DVB0
DWB0
U phase output buffer 0
Setting in U phase output buffer 0
V phase output buffer 0
W phase output buffer 0
U phase output buffer 0
V phase output buffer 0
W phase output buffer 0
Setting in V phase output buffer 0
Setting in W phase output buffer 0
Setting in V phase output buffer 0
Setting in U phase output buffer 0
Three-phase output buffer register 1 (Note)
Symbol
Address
When reset
IDB1
030B16
0016
Bit name
Function
Bit Symbol
W
R
b7
b6 b5
b4
b3
b2
b1
b0
Nothing is assigned.
When write, set "0". When read, its content is "0".
DU1
DUB1
DV1
DW1
DVB1
DWB1
U phase output buffer 1
Setting in U phase output buffer 1
V phase output buffer 1
W phase output buffer 1
U phase output buffer 1
V phase output buffer 1
W phase output buffer 1
Setting in V phase output buffer 1
Setting in W phase output buffer 1
Setting in V phase output buffer 1
Setting in U phase output buffer 1
Dead time timer (Note)
Symbol
Address
When reset
DTT
030C16
Indeterminate
Function
Values that can be set
W
R
b7
b0
Set dead time timer
1 to 255
Timer B2 interrupt occurrences frequency set counter (Note 1 to 3)
Symbol
Address
When reset
ICTB2
030D16
Indeterminate
Function
Values that can be set
W
R
b3
b0
Set occurrence frequency of timer B2
interrupt request
1 to 15
Note: When executing read instruction of this register, the contents of three-phase shift
register is read out.
Note: When executing read instruction of this register, the contents of three-phase shift
register is read out.
Note 1: When the effective interrupt output specification bit (INV01: bit 1 at 030816) is set to
"1" and three-phase motor control timer is operating, do not rewrite to this register.
Note 2: Do not write to this register at the timing of timer B2 overflow.
Note 3: Use MOV instruction to write to this register.
Note: Use MOV instruction to write to this register.
Figure 1.15.2. Registers related to timers for three-phase motor control