fields on the track as continuous blocks of data without regard to logical sector numbers. If the FDC finds an error in 
the ID or DATA CRC check bytes, it continues to read data from the track and sets the appropriate error bits at the 
end of the command.  The FDC compares the ID information read from each sector with the specified value in the 
command and sets the ND flag of Status Register 1 to a “1” if there no comparison.  Multi-track or skip operations are 
not allowed with this command. The MT and SK bits (bits D7 and D5 of the first command byte respectively) should 
always be set to “0”. 
This command terminates when the EOT specified number of sectors has not been read. If the FDC does not find an 
ID Address Mark on the diskette after the second occurrence of a pulse on the nINDEX pin, then it sets the IC code in 
Status Register 0 to “01” (abnormal termination), sets the MA bit in Status Register 1 to “1”, and terminates the 
command. 
SMSC DS – LPC47M192 
Page 56 
Rev. 03/30/05 
DATASHEET 
Table 22  –  Result Phase Table 
MT
0 
1 
HEAD
0 
1 
0 
1 
FINAL SECTOR 
TRANSFERRED TO
HOST
Less than EOT 
Equal to EOT 
Less than EOT 
Equal to EOT 
Less than EOT 
Equal to EOT 
Less than EOT 
Equal to EOT 
ID INFORMATION AT RESULT PHASE
C
H
NC 
NC 
C + 1 
NC 
NC 
NC 
C + 1 
NC 
NC 
NC 
NC 
LSB 
NC 
NC 
C + 1 
LSB 
R
N
NC 
NC 
NC 
NC 
NC 
NC 
NC 
NC 
R + 1 
01 
R + 1 
01 
R + 1 
01 
R + 1 
01 
NC:  No Change, the same value as the one at the beginning of command execution. 
LSB:  Least Significant Bit, the LSB of H is complemented. 
Write Data 
After the Write Data command has been issued, the FDC loads the head (if it is in the unloaded state), waits the 
specified head load time if unloaded (defined in the Specify command), and begins reading ID fields. When the sector 
address read from the diskette matches the sector address specified in the command, the FDC reads the data from 
the host via the FIFO and writes it to the sector’s data field. 
After writing data into the current sector, the FDC computes the CRC value and writes it into the CRC field at the end 
of the sector transfer. The Sector Number stored in “R” is incremented by one, and the FDC continues writing to the 
next data field.  The FDC continues this “Multi-Sector Write Operation”. Upon receipt of a terminal count signal or if a 
FIFO over/under run occurs while a data field is being written, then the remainder of the data field is filled with zeros.   
The FDC reads the ID field of each sector and checks the CRC bytes. If it detects a CRC error in one of the ID fields, 
it sets the IC code in Status Register 0 to “01” (abnormal termination), sets the DE bit of Status Register 1 to “1”, and 
terminates the Write Data command. 
The Write Data command operates in much the same manner as the Read Data command. The following items are 
the same. Please refer to the Read Data Command for details: 
Transfer Capacity 
EN (End of Cylinder) bit 
ND (No Data) bit 
Head Load, Unload Time Interval 
ID information when the host terminates the command 
Definition of DTL when N = 0 and when N does not = 0 
Write Deleted Data 
This command is almost the same as the Write Data command except that a Deleted Data Address Mark is written at 
the beginning of the Data Field instead of the normal Data Address Mark.  This command is typically used to mark a 
bad sector containing an error on the floppy disk.