IP101
IP101-DS-R0.02
Feb. 24, 2003
21 / 33
Copyright
2003, IC Plus Corp.
Confidential, All rights reserved.
Advanced, Specification subject to change without notice.
NOT APPROVED BY TECHNICAL DOCUMENT CONTROL
Power-Down Modes
IP101 can be power-down by 4 methods. These 4
methods are as follow:
1. Power Down in bit 11 of Register 0: Enable this bit
will disconnect the power to IP101 and also internal
clock, but MDC and MDIO are still activated.
2. APS mode in bit 1 of Register 16: Set high to this
bit will let PHY into power saving mode
3. Analog off in bit 0 of Register 16: Enable this bit will
put IP101 in analog off state. This will power down
all analog functions but not internal 25MHz
oscillator.
4. ISOL pin (pin 43): Set high will isolate IP101 from
MAC and disable management interface (MDC and
MDIO). The power usage is at minimum when this
pin is activated.
Repeater Modes
To enter Repeater mode, one can either set pin 40
(RPTR) to high or set 1 to bit 2 of Register 16 will allow
IP101 to enter Repeater mode. If IP101 is used in
repeater, CRS will be high if IC is in process of
receiving packets, while IP101 is used in a network
interface card, CRS will be generated in both
transmitting and receiving packets.
Miscellaneous
ISET (pin 28) should be connected to GND via a 6.2k
ohm resistor with 1% accuracy to ensure a correct
driving current for transmit DAC.
Set low to pin 42, REST_N, for at least 10ms will reset
all functions available in IP101. The bit 15 of Register 0
will put PHY into its default status.