21(+1) CHANNEL HIGH-DENSITY E1 LINE INTERFACE UNIT
Functional Description
54
December 7, 2005
3.4.8.2 Remote Loopback
Remote Loopback can be configured manually or automatically.
Either manual Remote Loopback configuration or automatic Remote
Loopback configuration will enable Remote Loopback.
Manual Remote Loopback is enabled by the RLP bit (b1, LOOP,...).
Automatic Remote Loopback is enabled when the pattern detection
is assigned in the receive path (i.e., the PD_POS bit (b3, PD,...) is ‘0’)
and the AUTOLP bit (b3, LOOP,...) is ‘1’. The corresponding channel will
enter Remote Loopback when the activate IB code is detected in the
receive path for more than 5.1 sec.; and will return from Remote Loop-
back when the deactivate IB code is detected in the receive path for
more than 5.1 sec. Refer to section Inband Loopback (IB) Detection on
page 49 for details. When automatic Remote Loopback is active, setting
the AUTOLP bit (b3, LOOP,...) back to ‘0’ will also stop automatic
Remote Loopback. The setting of the PD_POS bit (b3, PD,...) should not
be changed during automatic Remote Loopback. The AUTOLP_S bit
(b7, STAT0,...) indicates the automatic Remote Loopback status.
In Remote Loopback mode, the data stream output from the RJA (if
enabled) is internally looped to the Waveform Shaper. The data stream
received from the line side is still output to the system side, while the
data stream input from the system side is covered by the Remote Loop-
back data and the status on TCLKn does not affect the Remote Loop-
back. However, the BPV/CV, EXZ, SLOS, AIS and pattern detection in
the transmit path still monitors the data stream input from the system
side.
In Remote Loopback mode, the priority of the diagnostic facilities in
the receive path is: pattern generation > AIS generation; the priority of
the diagnostic facilities in the transmit path is: pattern generation >
looped data. AIS generation is disabled in the transmit path. Refer to
Figure-31 Priority Of Diagnostic Facilities During Manual Remote Loopback
Tx path
BPV/CV, EXZ, SLOS,
AIS, pattern detection
Pattern generation
AIS generation
X
Rx path
LLOS, AIS
detection
AIS generation
BPV/CV, EXZ,
pattern detection
Pattern generation
Remote
Loopback
相關PDF資料
PDF描述
IDT72V3652L15PQF IC BI FIFO 4096X36 15NS 132QFP
V48B12M250B3 CONVERTER MOD DC/DC 12V 250W
V48B12M250B2 CONVERTER MOD DC/DC 12V 250W
IDT72V3652L15PF IC BI FIFO 4096X36 15NS 120QFP
IDT82V2088DR IC LIU T1/J1/E1 8CH 208-TQFP
相關代理商/技術參數
參數描述
IDT82P2521BHBLANK 制造商:IDT 制造商全稱:Integrated Device Technology 功能描述:21(1) Channel High-Density E1 Line Interface Unit
IDT82P2521BHG 功能描述:IC LIU E1 21+1CH SHORT 640-PBGA RoHS:是 類別:集成電路 (IC) >> 接口 - 驅動器,接收器,收發(fā)器 系列:- 標準包裝:250 系列:- 類型:收發(fā)器 驅動器/接收器數:2/2 規(guī)程:RS232 電源電壓:3 V ~ 5.5 V 安裝類型:表面貼裝 封裝/外殼:16-TSSOP(0.173",4.40mm 寬) 供應商設備封裝:16-TSSOP 包裝:帶卷 (TR)
IDT82P2521BHGBLANK 制造商:IDT 制造商全稱:Integrated Device Technology 功能描述:21(1) Channel High-Density E1 Line Interface Unit
IDT82P2808 制造商:IDT 制造商全稱:Integrated Device Technology 功能描述:8(+1) Channel High-Density T1/E1/J1 Line Interface Unit
IDT82P2808BB 功能描述:IC LIU T1/J1/E1 8+1CH 416-PBGA RoHS:否 類別:集成電路 (IC) >> 接口 - 驅動器,接收器,收發(fā)器 系列:- 標準包裝:1,000 系列:- 類型:收發(fā)器 驅動器/接收器數:2/2 規(guī)程:RS232 電源電壓:3 V ~ 5.5 V 安裝類型:表面貼裝 封裝/外殼:16-SOIC(0.295",7.50mm 寬) 供應商設備封裝:16-SOIC 包裝:帶卷 (TR)