參數(shù)資料
型號: ICB1FL02G
廠商: INFINEON TECHNOLOGIES AG
英文描述: Smart Ballast Control IC for Fluorescent Lamp Ballasts
中文描述: 智能鎮(zhèn)流器控制芯片用于熒光燈鎮(zhèn)流器
文件頁數(shù): 15/37頁
文件大?。?/td> 1143K
代理商: ICB1FL02G
ICB1FL02G
Functional Description
Datasheet Version 1.2
15
February 2006
Figure 13
Maximum ratio of amplitudes versus sense current.
Furthermore the rectification effect (EOL2) is detected when the ratio of the higher amplitude divided by the
smaller amplitude of the lamp voltage is bigger than illustrated in Fig. 13. for longer than 500ms. The ratio is
evaluated each cycle of the lamp voltage. The limit of the ratio increases dependend on the peak current of the
smaller amplitude of the lamp voltage from 1,15 at I
LVS
= 200μA nonlinear to 1,4 at I
LVS
= 50μA.
If the EOL2 conditions are detected, the control is disabled and the status is latched as a failure mode. Measuring
the duration of incorrect operating conditions is done by a check every 4ms. If the fault condition is existing, a
counter counts up, if the fault condition is not existing, the counter counts down. So we get an integration of the
fault events that allows a very effective monitoring of strange operating conditions.
The detection of EOL1 and EOL2 requires an AC current input at the sense pins LVS1 and LVS2 for proper
operation. A DC current at pin LVS will lead to a defined reaction only, if the level exeeds 175μA (typically) for
longer than 610μs which results in a shut down and change over into the latched failure mode.
3.5
Detection of capacitive mode operating conditions
If there happens a situation like an open resonant circuit (e.g. a sudden break of the tube) the voltage across the
resonant capacitor and current through the shunt of the low-side inverter MOSFET rise quickly. This event is
detected by inverter current limitation (1,6V) and results in shut down of the control. This status is latched as a
failure mode.
In another kind of failure the operation of the inverter may leave the zero voltage switching (ZVS) and move into
capacitive mode operation or into operation below resonance. There are two different levels for capacitive mode
detection implemented in the IC. A first criteria detects low deviations from ZVS (CapLoad1) and changes
operation into fault mode, if this operation lasts longer than 500ms. For CapLoad1 the same counter is used as
for the end-of-life evaluation.
1
1,1
1,2
1,3
1,4
1,5
1,6
1,7
1,8
1,9
2
2,1
2,2
2,3
2,4
2,5
0
50
100
150
200
250
I
LVS
= Lamp Voltage / Sense Resistor [uA] of smaller Amplitude
R
相關(guān)PDF資料
PDF描述
ICE1QS01 Controller for Switch Mode Power Supplies Supporting Low Power Standby and Power Factor Correction (PFC)
ICE1QS01G Controller for Switch Mode Power Supplies Supporting Low Power Standby and Power Factor Correction (PFC)
ICE3AS02 Off-Line SMPS Current Mode Controller with integrated 500V Startup Cell
ICE3AS02G Off-Line SMPS Current Mode Controller with integrated 500V Startup Cell
ICE3BS02 Off-Line SMPS Current Mode Controller with integrated 500V Startup Cell
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
ICB1FL02G IFX 制造商:Infineon Technologies AG 功能描述:
ICB1FL02G_08 制造商:INFINEON 制造商全稱:Infineon Technologies AG 功能描述:Smart Ballast Control IC for Fluorescent Lamp Ballasts
ICB1FL02GXUMA1 制造商:Infineon Technologies AG 功能描述:Electronic Ballast Controller 12V/15V 100KHz T/R 制造商:Infineon Technologies AG 功能描述:Electronic Ballast Controller 12V/15V 100KHz 18-Pin DSO T/R 制造商:Infineon Technologies AG 功能描述:FL LIGHTING - Tape and Reel 制造商:Infineon Technologies AG 功能描述:IC SMART BALLAST CONTROL PDSO-18
ICB1FL03G 功能描述:LED照明驅(qū)動器 LIGHTING RoHS:否 制造商:STMicroelectronics 輸入電壓:11.5 V to 23 V 工作頻率: 最大電源電流:1.7 mA 輸出電流: 最大工作溫度: 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:SO-16N
ICB1FL03GXUMA1 制造商:Infineon Technologies AG 功能描述:ELECTRONIC BALLAST CONTROLLER 12V/15V 100KHZ 制造商:Infineon Technologies AG 功能描述:FL LIGHTING - Tape and Reel 制造商:Infineon Technologies AG 功能描述:IC SMART BALLAST CONTROL DSO18