138
Standby Power Supply
Current
ICCSB
VIN = VCC or
GND,
VCC = 5.5V,
Outputs Open
1, 2, 3
-55
o
C
≤
T
A
≤
+125
o
C
-
100
μ
A
Operating Power Supply
Current
ICCOP
f = 16.0MHz,
VIN = VCC or
GND
VCC = 5.5V,
CL = 50pF
1, 2, 3
-55
o
C
≤
T
A
≤
+125
o
C
-
18.0
mA
Functional Test
FT
(Note 2)
7, 8
-55
o
C
≤
T
A
≤
+125
o
C
-
-
-
NOTES:
1. Interchanging of force and sense conditions is permitted.
2. Tested as follows: f = 16MHz, VIH = 70% VCC, VIL = 20% VCC, VOH
≥
VCC/2, and VOL
≤
VCC/2, VCC = 4.5V and 5.5V.
TABLE 2. HD-6409/883 AC ELECTRICAL PERFORMANCE SPECIFICATIONS
Device Guaranteed and 100% Tested
PARAMETER
SYMBOL
(NOTE 1)
CONDITIONS
GROUP A
SUBGROUPS
TEMPERATURE
LIMITS
UNITS
MIN
MAX
Clock Frequency
fC
9, 10, 11
-55
o
C
≤
T
A
≤
+125
o
C
-
16
MHz
Clock Period
tC
9, 10, 11
-55
o
C
≤
T
A
≤
+125
o
C
1/fC
-
sec
Bipolar Pulse Width
t1
9, 10, 11
-55
o
C
≤
T
A
≤
+125
o
C
tC +10
-
ns
One-Zero Overlap
t3
9, 10, 11
-55
o
C
≤
T
A
≤
+125
o
C
-
tC - 10
ns
Clock High Time
tCH
f =16.0MHz
9, 10, 11
-55
o
C
≤
T
A
≤
+125
o
C
20
-
ns
Clock Low Time
tCL
f =16.0MHz
9, 10, 11
-55
o
C
≤
T
A
≤
+125
o
C
20
-
ns
Serial Data Setup Time
tCE1
9, 10, 11
-55
o
C
≤
T
A
≤
+125
o
C
120
-
ns
Serial Data Hold Time
tCE2
9, 10, 11
-55
o
C
≤
T
A
≤
+125
o
C
0
-
ns
DCLK to SDO, NVM
tCD2
9, 10, 11
-55
o
C
≤
T
A
≤
+125
o
C
-
40
ns
ECLK to BZO
tR2
9, 10, 11
-55
o
C
≤
T
A
≤
+125
o
C
-
40
ns
NOTES:
1. AC Testing as follows: f = 4.0MHz, VIH = 70% VCC, VIL = 20% VCC, Speed Select = 16X; VOH
≥
VCC/2, VOL
≤
VCC/2; VCC = 4.5V
and 5.5V; Input rise and fall times driven at 1 ns/V, Output load = 50pF.
TABLE 3. HD-6409/883 ELECTRICAL PERFORMANCE SPECIFICATIONS
PARAMETER
SYMBOL
CONDITIONS
NOTES
TEMPERATURE
LIMITS
UNITS
MIN
MAX
Input Capacitance
CIN
VCC = Open, f =1MHz
All Measurements are
referenced to device
GND
1, 2
T
A
= +25
o
C
-
10
pF
I/O Capacitance
CI/O
1, 2
T
A
=
+25
o
C
-
12
pF
Output Rise Time (All except CO)
tr
From 1.0 to 3.5V
CL = 50pF
1, 2
-55
o
C
≤
T
A
≤
+125
o
C
-
50
ns
TABLE 1. HD-6409/883 DC ELECTRICAL PERFORMANCE SPECIFICATIONS (Continued)
Device Guaranteed and 100% Tested
PARAMETER
SYMBOL
CONDITIONS
GROUP A
SUBGROUPS
TEMPERATURE
LIMITS
UNITS
MIN
MAX
HD-6409/883