2–46
Altera Corporation
Stratix II Device Handbook, Volume 1
May 2007
Digital Signal Processing Block
Figure 2–30. DSP Block Interface to Interconnect
A bus of 44 control signals feeds the entire DSP block. These signals
include clocks, asynchronous clears, clock enables, signed/unsigned
control signals, addition and subtraction control signals, rounding and
saturation control signals, and accumulator synchronous loads. The clock
signals are routed from LAB row clocks and are generated from specific
LAB rows at the DSP block interface.
LAB
Row Interface
Block
DSP Block
Row Structure
16
OA[17..0]
OB[17..0]
A[17..0]
B[17..0]
DSP Block to
LAB Row Interface
Block Interconnect Region
36 Inputs per Row
36 Outputs per Row
R4 Interconnect
C4 Interconnect
Direct Link Interconnect
from Adjacent LAB
Direct Link Outputs
to Adjacent LABs
Direct Link Interconnect
from Adjacent LAB
36
Control
12
16
18