E3X
E3X
5
External Diagnostic Input Function
With this function, light projection can be stopped when desired.
The
operation of the sensor can be checked with this function before
the
E3X is placed into actual operation.
E3X-A
Light is emitted from the projection fiber head when the self-diag-
nostic
input is ON. The sensor, however
, will not operate.
E3X-F
No
light is emitted
from the projection fiber head when self-diagnos
-
tic
input is ON.
/-VG
By
short-circuiting the
pink and blue cords, light projection can
be
stopped (with a short-circuit current of 0.2 mA max.).
Light projection
stops
Pink
(external-
check
Input)
Brown (+V)
Blue (0 V)
ON
OFF
Light
Pink
(external-
check
Input)
Brown (+V)
Blue (0 V)
NPN
T
ype
Short
Open
ON
OFF
ON
OFF
External-diagnostic input
(between blue and pink)
LED for light projection
Indicator
By
short-circuiting the brown and pink cords, light projection can
be
stopped (with a short-circuit current of 0.2 mA max.).
Light projection
stops
Pink
(external-
check
Input)
Blue (0 V)
Brown (+V)
ON
OFF
Light
Pink
(external-
check
Input)
Blue (0 V)
Brown (+V)
PNP
T
ype
Short
Open
ON
OFF
ON
OFF
External-diagnostic input
(between brown and pink)
LED for light projection
Indicator
Special Fiber Units
The
following special accessories are available (order separately).
Contact
your OMRON representative for the details.
Fiber Units with Special Length of Stainless
Steel Tube
Fiber
with dif
ferent lengths of stainless steel tubes are available.
Applicable Models
E32-TC200F (tube with 0.9 dia.)
E32-TC200B/DC200F (tube with 1.2 dia.)
E32-DC200B (tube with 2.5 dia.)
Appearance
The length can be ordered in increments of 10 mm between
10 mm
min. and 120 mm max.
Tolerance:
+
1.0 mm if L is 40 mm or less. and
+
2.0 if L is more
than
40 mm. (Note that standard Fiber Units have a 90-mm or
40-mm long stainless steel tube.)
L
41