E3X
E3X
2
Item
Manual Sensitivity Adjustment Knob
Makes adjustment possible without
screwdriver
. W
ater-resistance lost when used
(enclosure rating reduced to IP50).
E39-G3
Protective Cover
Application
Replacement part for cover supplied with
Amplifier Unit.
Model
Appearance
E39-G4
Amplifier Units
Item
Auto-tuning
High-sensitivity
E3X-H11
Model
Appearance
E3X-T11
E3X-T21
59
12
32
Light
source
Power supply voltage
Red LED (660 nm)
12 to 24 VDC
+
10%, ripple (p-p) 10% max.
10 to 30 VDC
+
10%, ripple
(p-p) 10% max.
35 mA max.
1 m sec max.
Current consumption
Response time
Control output
T
imer function
Self-diagnosis alarm output
50 mA max.
500
m
s max.
100 mA max. at 30 VDC, NPN open collector
---
---
OFF-delay timer (fixed to 40 ms), switch selectable
50 mA max. at 30 VDC, open
collector
---
V
ariable hysteresis function
T
uning monitor function
Remote tuning function/
Remote bank function
---
Indicator (red/green LED) and buzzer
---
0% to 20%
---
---
When ON, short-circuit the
blue and pink wires.
(Short-circuit the blue and
purple wires for remote bank
selection.):
Short-circuit voltage 3 V
max., short-circuit current
5 mA min.
When OFF
, open the blue
and pink wires: 9 V min.
(input voltage: 24 V max.),
response time 100 ms max.
when OFF
.
Output method
Light ON and Dark ON selector