E3X
E3X
35
Sensitivity Adjustment
E3X-T
1. Locate
the sensor head in the sensing range of the E3X.
2.
Set the mode selector to TUNING.
3. Locate
the object at
the sensing position and press the tuning
button.
Through-beam
Model
Reflective Model
Reflective Model
The tuning indicator (red) is lit.
The built-in buzzer beeps once.
Light is not
received.
Mark
Base
4. Move
the object and press the tuning button.
Through-beam Model
Reflective Model
Reflective Model
If tuning is OK:
The tuning indicator turns green.
The built-in buzzer beeps once.
The tuning indicator (red) is still lit.
The built-in buzzer beeps 3 times.
If tuning is NG:
Change
the position of the object and the sensing distance that
have
been
set and repeat from the beginning.
Light is received..
Mark
Base
5. Set the mode setting selector to RUN to complete the
sensitivity
setting on the E3X.
The tuning indicator (green) is OFF
.
6. Select the logical output required with the operation mode
selector.
Maximum
Sensitivity Setting
1.
Set the mode setting selector to TUNING.
2. Press
the tuning button, at
which time the object may or may
not
be located at the sensing position.
The tuning indicator (red) is lit.
The built-in buzzer beeps once.
3. Set the mode setting selector to RUN to complete the
maximum sensitivity setting on the E3X. It will take
approximately three seconds for the stable operation
indicator or light reception indicator to be lit. After the
maximum
sensitivity setting is completed, the tuning indicator
will
turn green and then it will be automatically turned OFF
in
approximately
three seconds. The maximum sensitivity of the
E3X can be automatically set regardless of the set distance or
light
reception.
Note:
The
sensitivity of the E3X-T1
1 and E3X-T21 are
set to max
-
imum
before shipping.