CDC338
PHASE-LOCK LOOP CLOCK DRIVER
WITH 3-STATE OUTPUTS
SCAS418 – MAY 1992 – REVISED FEBRUARY 1993
4
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
Input voltage range, V
I
(see Note 1)
Voltage range applied to any output in the high state or power-off state, V
O
Current into any output in the low state, I
O
Input clamp current, I
IK
(V
I
< 0)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–0.5 V to 7 V
–1.2 V to 7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–0.5 V to V
CC
+ 0.5 V
. . . . . . .
96 mA
–18 mA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–65
°
C to 150
°
C
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
recommended operating conditions (see Note 2)
MIN
MAX
UNIT
VCC
VIH
VIL
VI
IOH
IOL
TA
NOTE 2: Unused pins (input or I/O) must be held high or low.
Supply voltage
4.75
5.25
V
High-level input voltage
2
V
Low-level input voltage
0.8
V
Input voltage
0
VCC
–48
V
High-level output current
mA
Low-level output current
48
mA
°
C
Operating free-air temperature
–40
85
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
VIK
VCC = 4.75 V,
VCC = 4.75 V,
VCC = 4.75 V,
VCC = 4.75 V,
VCC = 5.25 V,
VCC = 5.25 V,
VCC = 5.25 V,
II = –18 mA
IOH = – 3 mA
IOH = – 48 mA
IOL = 48 mA
VI = VCC or GND
VO = 2.7 V
VO = 0.5 V
–1.2
V
VOH
2.5
V
2
VOL
II
IOZH
IOZL
0.5
±
1
50
V
μ
A
μ
A
μ
A
–50
ICC
VCC = 5.25 V,
VI= VCCor GND
VI = VCC or GND
5 25 V
IO = 0,
Outputs high
75
Outputs low
100
mA
Outputs disabled
70
Ci
Co
VI = 2.5 V or 0.5 V
VO = VCC or GND
pF
pF
All typical values are at VCC = 5 V, TA = 25
°
C.
P