ADE7753
–22–
REV. PrF 10/02
PRELIMINARY TECHNICAL DATA
to V x I x t. T he sinusoidal ripple in the Active Energy
calculation is also shown. Since the average value of a
sinusoid is zero, this ripple will not contribute to the energy
calculation over time. However, the ripple can be observed
in the frequency output, especially at higher output frequen-
cies. T he ripple will get larger as a percentage of the
frequency at larger loads and higher output frequencies. T he
reason is simply that at higher output frequencies the integra-
tion or averaging time in the Energy-to-Frequency conversion
process is shorter. As a consequence some of the sinusoidal
ripple is observable in the frequency output. C hoosing a
lower output frequency at CF for calibration can significantly
reduce the ripple. Also averaging the output frequency by
using a longer gate time for the counter will achieve the same
results.
t
E(t)
R
U
VI
4.
(1+ 2.
l
/8.9Hz)
sin(4.
.
.f t
l
f
f
l
VIt
Figure 38 – Output frequency ripple
L INE C Y C L E E NE R GY A C C UMUL A T ION MOD E
In L ine C ycle E nergy Accumulation mode, the energy
accumulation of the ADE7753 can be synchronized to the
Channel 2 zero crossing so that active energy can be accumu-
lated over an integral number of half line cycles. T he
advantage of summing the active energy over an integer
number of half line cycles is that the sinusoidal component
in the active energy is reduced to zero. T his eliminates any
ripple in the energy calculation. Energy is calculated more
accurately and in a shorter time because integration period
can be shortened. By using the line cycle energy accumula-
tion mode, the energy calibration can be greatly simplified
and the time required to calibrate the meter can be signifi-
cantly reduced. T he ADE7753 is placed in line cycle energy
accumulation mode by setting bit 7 (C Y C MODE) in the
Mode register. In L ine Cycle Energy Accumulation Mode
the ADE7753 accumulates the active power signal in the
LAENERGY register (Address 04h) for an integral number
of line cycles, as shown in Figure 39. T he number of half line
cycles is specified in the LINECYC register (Address 1Ch).
T he ADE7753 can accumulate active power for up to 65,535
half line cycles. Because the active power is integrated on an
integral number of line cycles, at the end of a line cycle energy
accumulation cycle the CYCEND flag in the Interrupt Status
register is set (bit 2). If the C Y C END enable bit in the
Interrupt Enable register is enabled, the
IRQ
output will also
go active low. T hus the
IRQ
line can also be used to signal
the completion of the line cycle energy accumulation. An-
other calibration cycle will start as long as the CYCMODE
bit in the Mode register is set. Note that the result of the first
calibration is invalid and should be ignored. T he result of all
subsequent line cycle accumulation is correct.
From Equations 6 and 10.
(
)
0
0
+
=
nT
nT
dt
t
f
f
VI
dt
VI
t
E
2
2
cos
9
1
)
(
π
(12)
where n is a integer and T is the line cycle period. Since the
sinusoidal component is integrated over a integer number of
line cycles its value is always zero.
T herefore:
+
=
nT
VIdt
0
=
E
0
(13)
E(t)
VInT
(14)
+
+
Σ
CALIBRATION
CONTROL
LINECYC[14:0]
Output from
LPF2
LPF1
FROM
CHANNEL 2
ADC
ZERO CROSS
DETECTION
ACCUMULATE ACTIVE
ENERGY IN INTERNAL
REGISTER AND UPDATE
THE LAENERGY REGISTER
AT THE END OF LINECYC
LINE-CYCLES
46
0
LAENERGY[23:0]
WDIV[7:0]
23
0
Figure 39 – Energy Calculation in Line Cycle Energy Accu-
mulation Mode
Note that in this mode, the 16-bit LINECY C register can
hold a maximum value of 65,535. In other words, the line
energy accumulation mode can be used to accumulate active
energy for a maximum duration over 65,535 half line cycles.
At 60Hz line frequency, it translates to a total duration of
65,535 / 120Hz = 546 seconds.
POSIT IVE ONLY ACCUMULAT ION MODE
In Positive Only Accumulation mode, the energy accumula-
tion is done only for positive power, ignoring any occurrence
of negative power above or below the no load threshold as
shown in Figure 40. T he ADE7753 is placed in positive only
Active Power
IRQ
Active Energy
PNEG PPOS
PNEG
Interrupt Status Registers
No-load
threshold
No-load
threshold
PNEG
PPOS
PPOS
Figure 40 – Energy Accumulation in Positive Only
Accumulation Mode
相關(guān)PDF資料
PDF描述
ADE7753ARS Active and Apparent Energy Metering IC with di/dt sensor interface
ADE7753ARSRL Active and Apparent Energy Metering IC with di/dt sensor interface
ADE7754 ADE7754
ADE7754AR ADE7754
ADE7754ARRL ADE7754
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
ADE7753_10 制造商:AD 制造商全稱:Analog Devices 功能描述:Single-Phase Multifunction Metering IC with di/dt Sensor Interface
ADE7753ARS 制造商:Analog Devices 功能描述:Single Phase Multifunction Metering IC 20-Pin SSOP 制造商:Rochester Electronics LLC 功能描述:- Bulk 制造商:Analog Devices 功能描述:IC SEMICONDUTOR ((NS))
ADE7753ARSRL 制造商:Analog Devices 功能描述:Single Phase Multifunction Metering IC 20-Pin SSOP T/R 制造商:Rochester Electronics LLC 功能描述:- Bulk
ADE7753ARSZ 功能描述:IC ENERGY METERING 1PHASE 20SSOP RoHS:是 類別:集成電路 (IC) >> PMIC - 能量測量 系列:- 產(chǎn)品培訓模塊:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 標準包裝:2,500 系列:*
ADE7753ARSZ 制造商:Analog Devices 功能描述:ENERGY METERING IC