XC18V00 Series In-System Programmable Configuration PROMs
DS026 (v4.0) June 11, 2003
Product Specification
1-800-255-7778 R Absolute Maximum Ratings
(1,2)
Recommended Operating Conditions
Quality and Reliability Characteristics
Symbol
Description
Value
Units
V
CCINT/
V
CCO
V
IN
V
TS
T
STG
T
SOL
T
J
Supply voltage relative to GND
–
0.5 to +4.0
V
Input voltage with respect to GND
–
0.5 to +5.5
V
Voltage applied to High-Z output
–
0.5 to +5.5
V
Storage temperature (ambient)
–
65 to +150
°
C
Maximum soldering temperature (10s @ 1/16 in.)
+220
°
C
Junction temperature
+125
°
C
Notes:
1.
Maximum DC undershoot below GND must be limited to either 0.5V or 10 mA, whichever is easier to achieve. During transitions, the
device pins can undershoot to
–
2.0V or overshoot to +7.0V, provided this over- or undershoot lasts less then 10 ns and with the
forcing current being limited to 200 mA.
Stresses beyond those listed under Absolute Maximum Ratings might cause permanent damage to the device. These are stress
ratings only, and functional operation of the device at these or any other conditions beyond those listed under Operating Conditions
is not implied. Exposure to Absolute Maximum Ratings conditions for extended periods of time might affect device reliability.
2.
Symbol
Parameter
Min
Max
Units
V
CCINT
V
CCO
Internal voltage supply
3.0
3.6
V
Supply voltage for output drivers for 3.3V operation
3.0
3.6
V
Supply voltage for output drivers for 2.5V operation
2.3
2.7
V
V
IL
V
IH
V
O
T
VCC
T
A
Low-level input voltage
0
0.8
V
High-level input voltage
2.0
5.5
V
Output voltage
0
V
CCO
50
V
V
CCINT
rise time from 0V to nominal voltage
(1)
Operating ambient temperature
1
ms
–
40
°
85
°
C
Notes:
1.
At power up, the device requires the V
power supply to monotonically rise from 0V to nominal voltage within the specified
V
rise time. If the power supply cannot meet this requirement, then the device might not perform power-on-reset properly. See
Figure 8
.
Symbol
Description
Min
Max
Units
T
DR
N
PE
V
ESD
Data retention
20
-
Years
Program/erase cycles (Endurance)
20,000
-
Cycles
Electrostatic discharge (ESD)
2,000
-
Volts