![](http://datasheet.mmic.net.cn/Exar-Corporation/XRT6164AIP-F_datasheet_107250/XRT6164AIP-F_4.png)
XRT6164A
4
Rev. 3.0.1
ELECTRICAL CHARACTERISTICS
Test Conditions: V
CC = 5V +/- 5%, T A = 25°C, Unless Otherwise Specified
Parameters
Min.
Typ.
Max. Units Conditions
DC Electrical Characteristics
Supply Voltage
4.75
5
5.25
V
Analog Supply Current
710
mA
Digital Supply Current
17
22
mA
Receiver
Input Signal
1
2.2
Vp
Measured from Pins 1 or 16 with Respect to Pin 2
Dynamic Range
10
dB
Maximum Cable Loss Range
Input Impedance
20
k
Measured Between Pins 1 and 16
Input Slicing Threshold
50
%
Percent of Peak Input Signal Amplitude
Input Bias Voltage
1.45
V
Measured at Pin 2
Loss of Signal Alarm Threshold
150
mVp
Measured from Pins 1 or 16 with Respect to Pin 2
Loss of Signal Alarm Level
1.5
dB
Difference Between Alarm-on and Alarm-off
Hysteresis
Levels
Peak Detector Leakage
-80
A
Data Output Low
0.4
V
Measured at Pins 5 or 12, I
OUT = +1.6mA
Data Output High
3.0
V
Measured at Pins 5 or 12, I
OUT = -40A
Alarm Output Low
0.4
V
Measured at Pin 3; I
OUT = +1.6mA
Alarm Output High
V
CC -
V
Measured at Pin 3; I
OUT = -40A
0.5
TCM Input Low Voltage
0.8
V
Measured at Pin 15; I
IN Min = -500A, I IN Max =
+5A
Transmitter
Input Low Voltage
0.8
V
Measured at Pins 6, 11; I
IN = -700A
Input High Voltage
2.2
V
Measured at Pins 6, 11; I
IN = +5A
Output Low Voltage
1.2
V
Measured at Pins 8, 10; I
OUT = -40mA
Output Low Current
40
mA
Measured at Pins 8, 10; V
OUT = 1V
Output Leakage Current
-100
A
Measured at Pins 8, 10; V
OUT = 10V Outputs in
off state
AC Electrical Characteristics
Receiver
Input Level
1
2.2
Vp
Pin 1, 16 with Respect to Pin 2 1
Output Rise Time
80
ns
Pins 5, 12; C L = 15pF, 10% to 90%
Output Fall Time
80
ns
Pins 5, 12; C L =15pF, 90% to 10%
Notes:
1. Higher input voltages are possible if a resistive input attenuator is used.
Bold face parameters are covered by production test and guaranteed over operating temperature range.