VLSI
Solution
y
DATASHEET
VS1001
K
2. CHARACTERISTICS&SPECIFICATIONS
2.6
Recommended Operating Conditions
Parameter
Analog and Digital Ground
Positive Analog
Ambient Operating Temperature
Symbol
AGND DGND
AVDD
Min
Typ
0.0
3.0
Max
Unit
V
V
C
2.5
1
-30
3.6
+85
1
If AVDD is below 2.8 V, distortion performance may be compromised.
The following values are to be used when the clock doubler is active:
Parameter
Positive Digital
Input Clock Frequency
Internal Clock Frequency
1
Symbol
DVDD
XTALI
CLKI
Min
2.3
Typ
2.7
12.288
24.576
Max
3.6
13
26
Unit
V
MHz
MHz
1
The maximum sample rate that may be decoded with correct speed is CLKI/512.
The following values are to be used when the clock doubler is inactive:
Parameter
Positive Digital
Input Clock Frequency
Internal Clock Frequency
1
Symbol
DVDD
XTALI
CLKI
Min
2.3
Typ
2.7
24.576
24.576
Max
3.6
26
26
Unit
V
MHz
MHz
1
The maximum sample rate that may be decoded with correct speed is CLKI/512.
Note: With higher than typical voltages, VS1001k may operate with CLKI upto 30..32 MHz. However,
the chips are not qualified for this kind of usage. If necessary, VLSI Solution Oy can qualify chips for
higher clock rates for quantity orders.
2.7
Digital Characteristics
Parameter
High-Level Input Voltage
Low-Level Input Voltage
High-Level Output Voltage at I
O
= -2.0 mA
Low-Level Output Voltage at I
O
= 2.0 mA
Input Leakage Current
Symbol
Min
Typ
Max
Unit
V
V
V
V
μ
A
0.7DVDD
0.3DVDD
0.7DVDD
0.3DVDD
1.0
Version 4.11,
2003-09-18