參數資料
型號: SI2400URT-EVB
廠商: Silicon Laboratories Inc
文件頁數: 8/94頁
文件大?。?/td> 0K
描述: BOARD EVAL FOR SI2400 ISOMODEM
標準包裝: 1
系列: ISOmodem®
主要目的: 電信,調制解調器
嵌入式:
已用 IC / 零件: SI2400
主要屬性: 雙路 RJ-11 連接至電話線路,音頻連接器
次要屬性: RS-232,TTL 串行和 USB 接口
已供物品: 板,調制解調器,電源
相關產品: SI2400-BS-ND - IC ISOMODEM SYSTEM-SIDE 16SOIC
SI2400-FS-ND - IC ISOMODEM SYST-SIDE DAA 16SOIC
336-1093-ND - IC ISOMODEM SYSTEM-SIDE 16SOIC
其它名稱: 336-1166
Si2400
16
Rev. 1.3
Use the ESC pin—To program the GPIO3 pin to
function as an ESCAPE input, set GPIO3
SE2[5:4] = 11b. In this setting, a positive edge
detected on this pin will return the modem to
command mode. The “ATO” string can be used to re-
enter data mode.
Use 9-bit data mode—If 9-bit data format with
escape is programmed, a 1 detected on bit 9 will
return the modem to command mode. (See Figure 2
on page 9.) This is enabled by setting
SE0[3] (ND) = 1b and S15[0] (NBE) = 1b. The ATO
string can be used to reenter data mode. Ninth bit
escape does not work in the security modes.
Use TIES—The time independent escape sequence
is a sequence of three escape characters (“+”
characters by default). Once these characters have
been recognized, the modem enters the Command
state without sending a confirming result code to the
terminal. The modem then starts an internal prompt
delay timer. From that point on if an AT<CR>
(attention) command is received before the timer
expires, the timer is stopped and the “O” response
code is sent to the terminal. This indicates that the
Si2400 is in command mode.
If any other data is received while the timer is
running, the timer is stopped, the device returns to
the online state, and the data appearing on TXD is
sent to the remote modem.
If the timer expires, a confirming “O” response code
is sent to the terminal indicating that the modem is in
command mode.
TIES is enabled by writing register
S14[5] (TEO) = 1b. Both the escape character “+”
and the escape time-out period are programmable
via registers S0F (TEC) and S10 (TDT), respectively.
Note: TIES is not the recommended escape solution for the
most robust designs. Any data string containing the
sequence “+++AT<CR>” will interrupt a data sequence
erroneously.
Whether using an escape method or not, when the
carrier is lost, the modem will automatically return to
command mode and report “N”.
5.2.2. 8-Bit Data Mode (8N1)
The 8-bit data mode is the default mode after power-up
or a reset and is set by SE0[3] (ND) = 0b. It is
asynchronous, full duplex, and uses a total of 10 bits
including a start bit (logic 0), 8 data bits, and a stop bit
(logic 1). Data received from the remote modem is
transferred from the Si2400 to the host on the RXD pin.
Data transfer to the host begins when the Si2400
asserts a logic 0 start bit on RXD. Data is shifted out of
the Si2400 LSB first at the DTE rate determined by the
SE0[2:0] (SD) setting and terminates with a stop bit.
Data from the host for transmission to the remote
modem is shifted to the Si2400 on TXD, beginning with
a start bit, LSB first at the DTE rate determined by the
SE0[2:0] setting and terminates with a stop bit. After the
middle of the stop bit time the Si2400 will begin looking
for a logic 1 to logic 0 transition signaling the start of the
next character on TXD to be sent to the line (remote
modem).
5.2.3. 9-Bit Data Mode (9N1)
The 9-bit data mode is set by SE0[3] (ND) = 1b. It is
asynchronous, full duplex, and uses a total of 11 bits
including a start bit (logic 0), 9 data bits, and a stop bit
(logic 1). Data received from the line (remote modem) is
transferred from the Si2400 to the host on the RXD pin.
Data transfer to the host begins when the Si2400
asserts a logic 0 start bit on RXD. Data is shifted out of
the Si2400 LSB first at the DTE rate determined by the
SE0[2:0] (SD) setting and terminates with a stop bit.
Data from the host for transmission to the line (remote
modem) is shifted to the Si2400 on TXD, beginning with
a start bit, LSB first at the DTE rate determined by the
S-Register SE0[2:0] (SD) setting and terminates with a
stop bit. After the middle of the stop bit time the Si2400
will begin looking for a logic 1 to logic 0 transition
signaling the start of the next character on TXD to be
sent to the line (remote modem).
The ninth data bit may be used to indicate an escape by
setting S15[0] (NBE) = 1b. In this mode, the ninth data
bit will normally be set to 0 when the modem is online.
When the ninth data bit is set to 1, the modem will go
offline into Command mode and the next frame will be
interpreted as an AT command. Data mode can be
reentered using the ATO command.
5.2.4. Flow Control
No flow control is needed if the DTE rate and DCE rate
are the same. If the serial link (DTE) data rate is set
higher than the line (DCE) rate of the modem, flow
control is required to prevent loss of data to the
transmitter.
To control data flow, the clear-to-send (CTS) pin is used.
As shown in Figure 2 on page 9, the CTS pin will
normally be high, and will be low whenever the modem
is able to accept new data. The CTS pin will go high
again as soon as a start bit is detected on the TXD pin
and will remain high until the modem is ready to accept
another character.
相關PDF資料
PDF描述
CM322522-1R8JL INDUCTOR CHIP 1.8UH 3225 SMD
496837-000 CABLE TERMINATION RG/U 178,404
VI-J72-EX CONVERTER MOD DC/DC 15V 75W
6374615-8 C/A LC-SC DUP 62.5/125, 8M
VE-B12-EY-S CONVERTER MOD DC/DC 15V 50W
相關代理商/技術參數
參數描述
SI2401 制造商:SILABS 制造商全稱:SILABS 功能描述:V.22BIS ISOMODEM㈢ WITH LOW-COST DAA
SI2401-C-FS 制造商:Silicon Laboratories Inc 功能描述:
SI2401DC-EVB 功能描述:子卡和OEM板 SI2401 Daughter Card RoHS:否 制造商:BeagleBoard by CircuitCo 產品:BeagleBone LCD4 Boards 用于:BeagleBone - BB-Bone - Open Source Development Kit
SI2401-FS 功能描述:電信線路管理 IC 2400b/s System Side 3rd Gen DAA Tech RoHS:否 制造商:STMicroelectronics 產品:PHY 接口類型:UART 電源電壓-最大:18 V 電源電壓-最小:8 V 電源電流:30 mA 最大工作溫度:+ 85 C 最小工作溫度:- 40 C 安裝風格:SMD/SMT 封裝 / 箱體:VFQFPN-48 封裝:Tray
Si2401FS08-EVB 功能描述:網絡開發(fā)工具 Si2401+Si3008 ISO modem Eval Board RoHS:否 制造商:Rabbit Semiconductor 產品:Development Kits 類型:Ethernet to Wi-Fi Bridges 工具用于評估:RCM6600W 數據速率:20 Mbps, 40 Mbps 接口類型:802.11 b/g, Ethernet 工作電源電壓:3.3 V