CCD area image sensor
S7170-0909, S7171-0909
I
Pin connections
Pin
No.
Symbol
1
2
3
4
OG
5
6
7
8
P2H
9
P1H
10
IG2H
11
IG1H
12
ISH
13
TG *
13
14
P2V
15
P1V
16
17
18
19
20
21
ISV
22
IG2V
23
IG1V
24
*13: Isolation gate between vertical register and horizontal register. In standard operation, TG should be applied the same pulse
as P2V.
S7170-0909
S7171-0909
Function
Symbol
RD
OS
OD
OG
SG
-
-
P2H
P1H
IG2H
IG1H
ISH
TG *
13
P2V
P1V
Th1
Th2
P-
P+
SS
ISV
IG2V
IG1V
RG
Function
Remark
(standard operation)
+12 V
R
L
=10 k to 100 k
+20 V
+3 V
Same pulse as P2H
RD
OS
OD
Reset drain
Output transistor source
Output transistor drain
Output gate
Summing gate
Reset drain
Output transistor source
Output transistor drain
Output gate
Summing gate
SG
-
-
CCD horizontal register clock-2
CCD horizontal register clock-1
Test point (horizontal input gate-2)
Test point (horizontal input gate-1)
Test point (horizontal input source)
Transfer gate
CCD vertical register clock-2
CCD vertical register clock-1
CCD horizontal register clock-2
CCD horizontal register clock-1
Test point (horizontal input gate-2)
Test point (horizontal input gate-1)
Test point (horizontal input source)
Transfer gate
CCD vertical register clock-2
CCD vertical register clock-1
Thermistor
Thermistor
TE-cooler-
TE-cooler+
Substrate (GND)
Test point (vertical input source)
Test point (vertical input gate-2)
Test point (vertical input gate-1)
Reset gate
0 V
0 V
Connect to RD
Same pulse as P2V
-
-
-
-
SS
Substrate (GND)
Test point (vertical input source)
Test point (vertical input gate-2)
Test point (vertical input gate-1)
Reset gate
GND
Connect to RD
0 V
0 V
RG
I
Specifications of built-in TE-cooler (S7171-0909)
Parameter
Internal resistance
Maximum current *
14
Maximum voltage
Maximum heat absorption *
17
Maximum temperature of heat radiating side
*14: Maximum current Imax:
If the current greater than this value flows into the thermoelectric cooler, the heat absorption begins to decrease due to the
Joule heat. It should be noted that this value is not the damage threshold value. To protect the thermoelectric cooler and
maintain stable operation, the supply current should be less than 60 % of this maximum current.
*15: Temperature of the cooling side of thermoelectric cooler.
*16: Temperature of the heat radiating side of thermoelectric cooler.
*17: Maximum heat absorption Qmax.
This is a theoretical heat absorption level that offsets the temperature difference in the thermoelectric cooler when the
maximum current is supplied to the unit.
(Typ. Ta=25
C)
Symbol
Rint
Imax
Vmax
Qmax
-
Condition
Typ.
2.1
2.0
4.2
4.5
70
Unit
A
V
W
°C
Ta=25 °C
Tc *
15
=Th *
16
=25 °C
Tc *
15
=Th *
16
=25 °C
VOLTAGE vs. CURRENT
CCD TEMPERATURE vs. CURRENT
0
1
2
3
V
C
C
4
6
5
-30
2.0
1.5
1.0
CURRENT (A)
0.5
0
-20
-10
0
10
20
30
KMPDB0180EA