DOT MATRIX LCD DRIVER
S-4520BA
4
Seiko Instruments Inc.
Note 9
Note 10 Current consumption by LCD panel and parasitic capacitance is not included.
Note 11 Current consumption when writing vertically-striped display data at t
CYC
=200 kHz. After the termination of command,
the current consumption value is I
DD1
.
Note 12 Reset time is from the point where RESX changed to the time when the reset operation is over and normal operation
becomes available.
Note 13 This is the inversion level of the input signal. Make the input signal go through the entire power supply voltage range
applied for the S-4520BA. If the input signal does not go the full range, current consumption will increase.
Note 14 When using a power supply voltage other than
5.0
±
0.5 V, the value is different. Check the power supply voltage.
Current consumption when circuits, for example the oscillation circuit, the MPU interface, etc, are not operating.
AC Electrical Characteristics
1. Raed/write with 80 family MPU
V
SS
=
5 V
V
SS
=
3 V
Parameter
Sym.
t
AH8
t
AW8
t
CYC8
t
CC
t
DS8
t
DH8
t
ACC8
t
OH8
Signal
Conditions
Min.
10
20
1000
200
100
10
50
Max.
110
130
Unit
ns
ns
ns
ns
ns
ns
ns
ns
Address hold time
Address setup time
System cycle time
Control pulse width
Data setup time
Data hold time
RDX access time
Output disable time
CL=100pF
CL=100pF
Parameter
Sym.
t
AH8
t
AW8
t
CYC8
t
CC
t
DS8
t
DH8
t
ACC8
t
OH8
Signal
Conditions
Min.
20
40
2000
400
200
20
25
Max.
220
260
Unit
ns
ns
ns
ns
ns
ns
ns
ns
Address hold time
Address setup time
System cycle time
Control pulse width
Data setup time
Data hold time
RDX access time
Output disable time
CL=100pF
CL=100pF
Table 5
(Ta=
20 to 75
°
C, V
SS
=
5 V
±
10%)
A
0
WRX, RDX
D
0
to D
7
Table 6
(Ta=
20 to 75
°
C, V
SS
=
3 V
±
10%)
A
0
WRX, RDX
D
0
to D
7
t
AW8
t
CC
t
CYC8
t
AH8
t
DS8
t
DH8
t
ACC8
t
OH8
A
0
WRX, RDX
D
0
to D
7
(WRITE)
D
to D
(READ)
Figure 2 Read/write timing with 80 family MPU