參數(shù)資料
型號: PDIUSBD11
廠商: NXP Semiconductors N.V.
英文描述: USB device with serial interface
中文描述: USB設(shè)備的串行接口
文件頁數(shù): 8/20頁
文件大?。?/td> 119K
代理商: PDIUSBD11
Philips Semiconductors
Product specification
PDIUSBD11
USB device with serial interface
1999 Jul 22
8
Clock Division Factor Byte
SV00828
7
X
6
X
5
X
4
X
3
1
2
0
1
1
1
0
POWER ON VALUE
CLOCK DIVISION FACTOR
RESERVED
Clock Division Factor
The value indicates clock division factor for
CLKOUT. The output frequency is
48 MHz/(N+1) where N is the Clock Division
Factor. The reset value is 11. This will
produce the output frequency of 4 MHz
which can then be programmed up (or down)
by the user. The minimum value is one giving
the range of frequency from 4 to 24 MHz.
The PDIUSBD11 design ensures no
glitching during frequency change. The
programmed value will not be changed by a
bus reset.
Data Flow Commands
Data flow commands are used to manage the data transmission
between the USB endpoints and the monitor. Much of the data flow
is initiated via an interrupt to the microcontroller. The microcontroller
utilizes these commands to access and determine whether the
endpoint FIFOs have valid data.
Read Interrupt Register
Command
Data
: F4h
: Read 2 bytes
Interrupt Register Byte 1
POWER ON VALUE
RESERVED
CONTROL OUT ENDPOINT
CONTROL IN ENDPOINT
ENDPOINT INDEX 4
ENDPOINT INDEX 5
ENDPOINT INDEX 6
ENDPOINT INDEX 7
7
0
6
0
5
0
4
0
3
0
2
0
X
1
X
0
SV00829
This command indicates the origin of an interrupt. A ‘1’ indicates an
interrupt occurred at this endpoint. The bits are cleared by reading
the endpoint status register through the Read Endpoint Status
command.
After a bus reset, an interrupt will be generated and bit 6 of the
Interrupt Register Byte 2 will be ‘1’. The interrupt is internally cleared
by reading the interrupt register. A bus reset is completely identical
to the hardware reset through the RESET_N pin with the sole
difference of interrupt notification.
Interrupt Register Byte 2
POWER ON VALUE
ENDPOINT INDEX 8
ENDPOINT INDEX 9
RESERVED
BUS RESET
RESERVED
7
X
6
0
5
X
4
X
3
X
2
X
0
1
0
0
SV00830
Select Endpoint
Command
Data
: 00-0Dh
: Optional Read 1 byte
The Select Endpoint command initializes an internal pointer to the
start of the Selected buffer. Optionally, this command can be
followed by a data read, which returns ‘0’ if the buffer is empty and
‘1’ if the buffer is full.
7
X
6
X
5
X
4
X
3
X
2
X
X
1
0
0
POWER ON VALUE
FULL/EMPTY
RESERVED
SV00831
Full/Empty
A ‘1’ indicates the buffer is full, ‘0’ indicates an
empty buffer.
相關(guān)PDF資料
PDF描述
PDIUSBD11N USB device with serial interface
PDIUSBD12 nullUSB interface device with parallel bus
PDUSBD12PWDH nullUSB interface device with parallel bus
PDIUSBD12D nullUSB interface device with parallel bus
PDIUSBD12PW nullUSB interface device with parallel bus
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
PDIUSBD11D 制造商:PHILIPS 制造商全稱:NXP Semiconductors 功能描述:USB device with serial interface
PDIUSBD11D-T 制造商:未知廠家 制造商全稱:未知廠家 功能描述:BUS CONTROLLER
PDIUSBD11N 制造商:PHILIPS 制造商全稱:NXP Semiconductors 功能描述:USB device with serial interface
PDIUSBD11NB 制造商:未知廠家 制造商全稱:未知廠家 功能描述:BUS CONTROLLER
PDIUSBD12 制造商:Panasonic Industrial Company 功能描述:IC